Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Idea Factory Service Manual (2003-2012)22 · Fault diagnosis
22 · Diagnostics

Climate control not working / under no circumstances

Make
Fiat
Model
Idea Factory Service Manual
Year
2003–2012
Section
Climate control › Climate control not working / under no circumstances
Fault diagnosisClimate control not working / under no circumstances

CLIMATE CONTROL NOT WORKING / UNDER NO CIRCUMSTANCES

When the appropriate on/off button is pressed, the climate control sytem does not work.

The climate control Node supply is protected by special fuses;

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation

check

  • the condition of the climate control system supply protective fuses See E6020 AIR CONDITIONING
  • that the climate control system gas pressure is correct
Continue to Step 1Fuses blownChange blown fuses
Relay damagedReplace relay
Gas pressure not correctEliminate leaks and top up climate control system
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment and check for errors:

  • in the climate control system node.
  • in the CAN line;
Continue to Step 4Climate control system node not working.Continue to Step 2
CAN line error.Continue following the instructions for the diagnostic equipment.
2ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the climate control system node power supply See E6020 AIR CONDITIONINGContinue to Step 3No power supplyRestore broken electrical connection See E6020 AIR CONDITIONING
3CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections for the climate control system node, in particular making sure that each individual pin is correctly connected and inserted in its housing.Continue to Step 4Electrical connections not working.Restore damaged electrical connection.
4CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Keep the Examiner connected and check the engine control Node in parameter mode for:

Check the condition of the compressor control wiring (no short-ciruits or open circuits)

Continue to Step 5Relay not working.Change compressor control relay
Wiring faultyRenew the wiring
Error at linear sensorContinue to Step 5
Electric fan defectiveReplace the fan
Fan wiring interruptedRenew the wiring
5COMPRESSOR ENGAGEMENT CHECKAll OKProblems metOperation
Check correct compressor activation by carrying out the test See Test 5040BC Check activation/deactivation of climate control compressor from linear sensorContinue to Step 6The compressor does not come onCheck continuity/insulation of electrical connection between engine control unit and climate control system pressure sensor. See E6021 COMPRESSOR ENGAGEMENT
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check continuity/insulation of electrical connection between engine control unit and climate control system pressure sensor.End of diagnosis

Parts & tools for this job For 2003 Fiat Idea

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.