Climate control not cooling
- Make
- Fiat
- Model
- Ulysse Factory Service Manual
- Year
- 2002–2010
- Section
- Climate control › Climate control not cooling
CLIMATE CONTROL NOT COOLING
The compressor comes on, the fan works normally and sends air to the passenger compartment according to the pre-set flows bu the air remains at the outside temperature and is not cooled.
The enablement of the engagement of the refrigerant circuit is controlled by both the climate control system control unit and the engine management control unit. Therefore if the climate control system is not cooling in certain conditions, this is correct.
| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | ||
|---|---|---|---|---|
| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the condition of the compressor drive beltCheck the system pressure | Move on to Step | 1. Belt deteriorated or broken | 1. Replace the belt | |
| 2. Gas pressure does not conform. | 2. Eliminate leaks and top up climate control system to correct level | |||
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the following using the Examiner diagnostic equipment:
| Move on to Step | 1. Presence of errors at the engine management node. | Move on to Step | |
| 2. Presence of errors at the climate control node | Move on to Step | |||
| 3. Presence of errors at the Body computer. | Move on to Step | |||
| 4. Presence of errors at the VAN CONFORT network. | Move on to Step | |||
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Move on to Step | 1. Errors present | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Parameters not plausible | 2. Continue following the instructions for the diagnostic equipment | |||
| 3. No communication between climate control system control unit | 3. Restore connection between the climate control unit and diagnostic connector | |||
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:
| Move on to Step | 1. Presence of faults | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Parameters not plausible | 2. Continue following the instructions for the diagnostic equipment | |||
| 3. Climate control circuit pressure not correct | Move on to Step | |||
| 4. No dialogue with the engine management control unit | 4. Restore connection between the climate control unit and diagnostic connector | |||
Parts & tools for this job For 2002 Fiat Ulysse
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Fiat Ulysse 2002 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.