Climate control not heating
- Make
- Fiat
- Model
- Ulysse Factory Service Manual
- Year
- 2002–2010
- Section
- Climate control › Climate control not heating
CLIMATE CONTROL NOT HEATING
The climate control works properly and sends air to both the left and right sides of the passenger compartments according to the pre-set flows, but this air does not ensure the heating required.
| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | ||
|---|---|---|---|---|
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
With the (Examiner or other) diagnostic equipment connected, check the following:
| Move on to Step | 1. Presence of faults | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Climate control system control unit error | Move on to Step | |||
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:
| Move on to Step | 1. Error detected in the control unit | 1. Continue following the instructions for the diagnostic equipment | |
| 2. No communication with the control unit | 2. Restore the connection between the climate control system control unit and the diagnostic connector | |||
| 3 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis of the mixing motors | Move on to Step | mixing motor(s) not working | Move on to Step | |
| 4 | ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the condition of the electrical circuit for the mixing motors | Move on to Step | 1. Mixing motor(s) electrical circuit faulty | 1. Repair the connections | |
| 2. Connections correct, right motor defective | 2. Replace the motor Op. 5040D86 AIR CONDITIONER RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R R | |||
| 3. Connections correct, left motor defective | 3. Replace the motor Op. 5040D84 AIR CONDITIONER LEFT HAND AIR MIXER FLAP CONTROL MOTOR - R R | |||
| 5 | HEATER HYDRAULIC CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check:
| Move on to Step | 1. Air in the circuit | 1. Bleed the heater circuit | |
| 2. No pipe seal | 2. Renew the seal, if necessary, replace the pipe | |||
| 6 | HEATER RADIATOR CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the efficiency of the heater radiator | Move on to Step | Radiator dirty or obstructed | Clean the radiator, if necessary, replace it | |
| 7 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | ||||