Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control too cold

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Climate control › Climate control too cold
Fault diagnosisClimate control too cold

CLIMATE CONTROL TOO COLD

The control button activates the passenger compartment fan properly but the temperature of the air is not correct.

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • that there are no errors in the climate control system node (NCL)
  • parameter plausibility.
Move on to Step1. Presence of errors.1. Continue following the instructions for the diagnostic equipment
2. Parameters not plausible2. Continue following the instructions for the diagnostic equipment
3. No communication between climate control system control unit

3. Restore connection between the climate control unit and diagnostic connector

See E6020 AIR CONDITIONING

2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • that there are no faults in the engine management node.
  • parameter plausibility
Move on to Step1. Presence of faults.1. Continue following the instructions for the diagnostic equipment
2. Parameters not plausible.2. Continue following the instructions for the diagnostic equipment
3. No dialogue with the engine management control unit

3. Restore the connection between the engine management control unit and the diagnostic connector

See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT

2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
  • that there are no faults in the engine management node
  • parameter plausibility
Move on to Step1. Presence of faults1. Continue following the instructions for the diagnostic equipment
2. Parameters not plausible2. Continue following the instructions for the diagnostic equipment
3. No dialogue with the engine management control unit3. Restore the connection between the engine management control unit and the diagnostic connector
3AIR TEMPERATURE CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the temperature of the air at the ventsMove on to StepTemperature not correctMove on to Step
4SYSTEM PRESSURE CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Connect the climate control system to the special repressurizing equipment and check the system pressures

See Test 5040B SYSTEM SAFETY CHECK DEVICES

Move on to Step1. High and Low pressure values below the correct figures

1. Repressurize the system

Op. 5040A10 EXPANSION/CONNECTION PIPE - R R

2. High and Low pressure values above the correct figuresMove on to Step
3. High and Low pressure values do not alter when the air conditioning is activated.

3. Replace the compressor

Op. 5040A10 EXPANSION/CONNECTION PIPE - R R

4. Condenser cooling fan is not activated/deactivated at the correct pressuresMove on to Step
5CIRCUIT CAHRGE CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the system charge is not too high.Move on to StepSystem charge too high.

Restore the correct charge

Op. 5040A10 EXPANSION/CONNECTION PIPE - R R

6COOLANT CIRCUIT OBSTRUCTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the pipes and the filter are not obstructed.Move on to Step1. Pipe from compressor to condenser obstructed1. Replace the pipe
2. Pipe from condenser to filter obstructed2. Replace the pipe
3. Pipe from filter to expansion valve obstructed3. Replace the pipe
4. Filter obstructed

4. Replace the filter

Op. 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R

7CONDENSER CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the condenser is not blocked.Move on to StepCondenser blocked

Replace the condenser

Op. 5040A40 AIR CONDITIONER CONDENSER - R+R

8EXPANSION VALVE CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the operation of the expansion valve.Move on to StepExpansion valve defective

Replace the expansion valve

Op. 5040B30 EXPANSION VALVE (TUBE ORIFICE) - R+R

9CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the climate control node.

Parts & tools for this job For 2002 Fiat Ulysse

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.