01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)22 · Fault diagnosis
22 · Diagnostics

Passenger side temperature adjustment does not work

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Climate control › Passenger side temperature adjustment does not work
Fault diagnosisPassenger side temperature adjustment does not work

PASSENGER SIDE TEMPERATURE ADJUSTMENT DOES NOT WORK

When the desired passenger side temperature is set, there is no corresponding flow of air at the required temperature.

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment to the diagnostic socket and check:

  • that there are no errors in the climate control node (NCL)
Move on to Step1. Presence of faults1. Continue following the instructions for the diagnostic equipment
2. No communication with the control unit

2. Restore the connections between the control unit and the diagnostic socket

See E6020 AIR CONDITIONING

2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis of the mixing motor on the side where the error occurs.Move on to StepMixing motor not workingMove on to Step
3PASSENGER SIDE MIXING MOTOR ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • connection between the climate control node (NCL) and the mixing motor on the side where the error occurs.
Move on to Step1. Connections not correct.

1. Restore the correct connection

See E6020 AIR CONDITIONING

2. Connections correct, mixing motor faulty.

2. Check the condition of the flap, if necessary, replace the motor

Op. 5040D86 AIR CONDITIONER RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R R

4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persists.Replace the climate control system control unit