01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation not working

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Climate control › Climate control recirculation not working
Fault diagnosisClimate control recirculation not working

CLIMATE CONTROL RECIRCULATION NOT WORKING

The climate control recirculation does not work in any conditions (manual/automatic)

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check:That there are no errors in the climate control node (NCL)Move on to Step1. Error in the control unit.1. Check the NCL supply connections. Move on to Step
2. Recirculation motor error.Move on to Step
3. No communication with the NBC.

3. Restore the connection between the climate control node (NCL) and the NBC

See E6020 AIR CONDITIONING

2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis for the recirculation motor.Move on to StepRecirculation system stuck.Move on to Step
3MOTOR ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the recirculation motor electrical circuit

See E6020 AIR CONDITIONING

Move on to StepRecirculation motor connection faulty

Restore the correct connection

See E6020 AIR CONDITIONING

4ASSEMBLY MECHANICAL SECTION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the recirculation flap moves freely.Move on to StepRecirculation flap mechanical section faulty.Repair/replace the defective parts.
5CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present.Fault persistsReplace the Climate control system node (NCL)