01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control not working / under no circumstances

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Climate control › Climate control not working / under no circumstances
Fault diagnosisClimate control not working / under no circumstances

CLIMATE CONTROL NOT WORKING / UNDER NO CIRCUMSTANCES

The climate control system will not work when the controls are operated.

The climate control only works with the engine running.

The nodes involved in the operation of the climate control are: NCL - NBC - NDVM - NCM

The networks go on stand-by 30 mins after the engine is switched off. This makes it impossible to carry out the fault diagnosis. If a diagnostic session has to be opened, start up the engine to reawaken the networks.

1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Check the following with the EXAMINER connected to the NCM node is the errors ambient:

  • that there are no errors.
Move on to Step1. Climate control system pressure error.Move on to Step
2. Air conditioning control error2. CAN check.Move on to Step
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Check the following at the Body Computer Node (NBC):In active diagnosis ambient - Compressor engagement.In errors ambient - that there are no errors.Move on to Step1. Compressor does not switch on.1. Check connection between compressor coupling and NDVM.
2. Climate control compressor errorMove on to Step
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • that there are no faults in the climate control system node (NCL).
Move on to Step1. Presence of faults1. Continue following the instructions for the diagnostic equipment
2. No communication with the control unitMove on to Step
4CHECK CONTINUITYALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • Wiring between linear pressure switch and NCM.
Move on to StepConnections not correct.

Restore the connections

See E6020 AIR CONDITIONING

5COMPRESSOR ENGAGEMENT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check that the compressor switches on correcly by

See Test 5040BC CLIMATE CONTROL COMPRESSOR LINEAR SENSOR ON/OFF CHECK

Move on to StepCompressor does not switch onMove on to Step
6CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check the compressor coupling continuity and insulation using a multimeter.Move on to StepCompressor coupling defective.Replace the compressor
7CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the linear sensor
8CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the climate control node (NCL)