TD5 Defender
ENGINE MANAGEMENT SYSTEM
19
DESCRIPTION AND OPERATION
The EUI can fail if one or more of the following occurs:
•
Open circuit.
•
Short circuit to voltage supply.
•
Short circuit to vehicle earth.
•
Wiring loom fault.
•
Connector water ingress.
•
Connector failure due to excess heat.
In the event of an EUI failure, any of the following symptoms may be observed:
•
Engine misfire.
•
Idle faults.
•
Reduced engine performance.
•
Reduced fuel economy.
•
Difficult cold start.
•
Difficult hot start.
•
Excess smoke.