Abortion of start procedure
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heater D3W › Abortion of start procedure
Supplementary heatingAbortion of start procedure
Abortion of start procedure
The start procedure is aborted if:
- Flame monitor G64 registers that the flame is not burning normally within 130 seconds.
- The temperature or overheating sensor detects a temperature greater than∼125°C.
- The temperature difference between the temperature and overheating sensors exceeds 15°C.
- Heater control unit J162 detects a fault.