Checking overheating sensor G189
Remove heater unit → Chapter.
Remove heater control unit J162Chapter.
Pull the connector housing off heater control unit J162.
Measure the resistance between chamber 5 and chamber 6 at the red cables.
R = Resistance kΩ

t = Temperature °C
Measure the resistance at the prevailing temperature.
- Defective > 2mΩ = Interruption
- Defective < 50 kΩ = Short circuit