Checking:
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heater D3W › Checking:
Checking:
Note
- If the ambient temperature is above 20°C, fuel vaporisation may lead to incorrect measurements.
- Hold measuring glass at same height as heater unit during measurement.
- No bubbles are to be delivered.
Set measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect test probes to contacts -T4a/4- (positive) and -T4a/3- (negative) of heater control unit J65.
Start the engine.
When the 8-pin connector is connected to basic unit VAS 5019, fuel pump G23 starts supplying fuel after approx. 40 seconds.
Fuel supply is switched off automatically after 90 seconds.
Switch ignition off and wait for run-on period to end.
Disconnect 8-pin connector on basic unit VAS 5019.
Compare quantity of fuel delivered (in measuring glass) with the value in the table.
Fuel delivery is ok when the quantity of fuel in the measuring glass corresponds with the values in the table.
If the quantity of fuel delivered does not correspond with the values in the table:
Renew fuel pump G23.
| Heater type | Quantity of fuel delivered in ml |
|---|---|
| D3W | 8 to 9 |