Start procedure
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heater D3W › Start procedure
Start procedure
After each engine start the flame monitor G64 must inform the heater control unit J162 within 130 seconds after the heating has switched on, that the flame is burning normally. If this not the case, then the heater unit will automatically attempt a second start. If, after the second start, the flame still does not burn normally, the heater will remain switched off until the engine is started again.
In partial load mode, the combustion air blower operates at reduced rpm and fuel pump G23 delivers only approx. 50% of the quantity of fuel (reduced pulse frequency).
Parts & tools for this job For 1990 Volkswagen Transporter
- FLUIDCoolantSearch: Volkswagen coolant antifreeze
- PARTThermostatSearch: Volkswagen Transporter 1990 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.