Checking flame monitor G64
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heater D3W › Checking flame monitor G64
Supplementary heatingChecking flame monitor G64
Checking flame monitor G64
Remove heater unit → Chapter.
Remove heater control unit J162Chapter.
Pull the connector housing off heater control unit J162.
Measure the resistance between chamber 2 and chamber 1 at the brown and blue cable:
R = Resistance Ω

t = Temperature °C
Measure the resistance at the prevailing temperature.
- Defective > 3040 Ω = Interruption
- Defective < 780 Ω = Short circuit
Parts & tools for this job For 1990 Volkswagen Transporter
- FLUIDCoolantSearch: Volkswagen coolant antifreeze
- PARTThermostatSearch: Volkswagen Transporter 1990 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.