Test sequence
- Make
- Volkswagen
- Model
- Transporter T4
- Year
- 1990–2003
- Section
- Auxiliary coolant heater D3W › Test sequence
Test sequence
Disconnect 8-pin connector T8 at the heater unit.
Set the measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20V.
Connect hand multimeter V.A.G 1526B to chamber “T8/2” and chamber “T8/6” of the disconnected 8-pin connector T8 using the cables included in auxiliary measuring set V.A.G 1594C.

Switch on the ignition.
Display on the hand multimeter V.A.G 1526B:
- At ambient temperatures below +5°C ≈ 12 V
- At ambient temperatures above +5°C ≈ 0 V
Unclip ambient temperature switch F38(1) from the bracket at front left in plenum chamber.

Spray ambient temperature switch F38 with cold spray, if necessary, and observe the display on hand multimeter V.A.G 1526B.
If the values do not change when ambient temperature switch F38 is sprayed, or if the specified rated values are not achieved:
Check the wiring and/or connectors to ambient temperature switch F38Current flow diagrams, Electrical fault finding and Fitting locations.
If the wiring and/or connectors to ambient temperature switch F38 are OK according to the current flow diagram:
Renew ambient temperature switch F38.
Note
- Ambient temperature switch F38 only switches the auxiliary coolant heater on automatically if the coolant temperature is below approx. 74°C and the ambient temperature is below approx. +5°C.
Parts & tools for this job For 1990 Volkswagen Transporter