- The following table lists all the faults, with the corresponding 3-digit code numbers, that can be detected by heater control unit J162.
| Display fault code number and meaning | Possible cause of fault | Remark / Rectifying fault |
|---|---|---|
| 000 | ||
| No malfunction | ||
| 010 | ||
| Overvoltage shutdown | Alternator C defective. | Check alternator C. Current flow diagrams, Electrical fault finding and Fitting locations |
| 011 | ||
| Undervoltage shutdown | Vehicle battery flat. | Check and charge battery. |
| Wiring or connectors to heater control unit J162 defective. | Check wiring and connectors using current flow diagram. | |
| Alternator C defective. | Check alternator C. Current flow diagrams, Electrical fault finding and Fitting locations | |
| 012 | ||
| 014 | Combustion air intake or exhaust system blocked. | Carry out visual check. |
| 017 | Coolant circuit has not been bled properly. | Check coolant circuit Rep. Gr.19. |
| Overheated, shutdown after 3x overheating | Quantity of fuel delivered not ok. | Check quantity of fuel delivered → Chapter. |
| 020 | ||
| Interruption, glow plug for heater Q9 | Glow plug for heater Q9 defective. | Renew glow plug for heater Q9Chapter. |
| 021 | ||
| Overload at glow plug output | Glow plug for heater Q9 defective. | Renew glow plug for heater Q9Chapter. |
| 030 | ||
| 031 | ||
| 032 | Interruption in wiring from heater control unit J162, contact -T10/2-, via combustion air blower V6 to heater control unit J162, contact -10/1-. | Check wiring and connectors using current flow diagram. |
| Motor for combustion air blower V6 does not rotate | Combustion air blower V6 defective | Renew combustion air blower V6. |
| 047 | ||
| Short circuit, fuel pump G23 | Short circuit in wiring from heater control unit J162, contact -T8/4-, via fuel pump G23 to heater control unit J162, contact -T8/3-. | Check wiring and connectors using current flow diagram. |
| Fuel pump G23 defective. | Renew fuel pump G23Chapter. | |
| 048 | ||
| Interruption, fuel pump G23 | Interruption in wiring from heater control unit J162, contact -T8/4-, via fuel pump G23 to heater control unit J162, contact -T8/3-. | Check wiring and connectors using current flow diagram. |
| Fuel pump G23 defective. | Renew fuel pump G23Chapter. | |
| 051 | ||
| Flame monitor G64 defective | Flame monitor G64 defective | Renew flame monitor G64Chapter. |
| 052 | ||
| Safety time exceeded, no flame | Combustion air intake or exhaust system blocked. | Carry out visual check. |
| Quantity of fuel delivered not ok. | Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter. | |
| Glow plug for heater Q9 defective. | Renew glow plug for heater Q9Chapter. | |
| 054 | ||
| Flame failure in “HIGH” stage | Quantity of fuel delivered not ok. | Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter. |
| 056 | ||
| Flame failure in “LOW” stage | Quantity of fuel delivered not ok. | Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter. |
| 060 | ||
| Interruption, temperature sensor G18 | Interruption in wiring and connectors to temperature sensor G18. | Check wiring and connectors using current flow diagram. |
| Temperature sensor G18 defective. | Renew temperature sensor G18. | |
| 061 | ||
| Short circuit, temperature sensor G18 | Short circuit in wiring and connectors to temperature sensor G18. | Check wiring and connectors using current flow diagram. |
| 064 | ||
| Interruption, flame monitor G64 | Interruption in wiring and connectors to flame monitor G64. | Check wiring and connectors using current flow diagram. |
| Flame monitor G64 defective | Renew flame monitor G64Chapter. | |
| 065 | ||
| Short circuit, flame monitor G64 | Short circuit in wiring and connectors to flame monitor G64. | Check wiring and connectors using current flow diagram. |
| Flame monitor G64 defective | Renew flame monitor G64Chapter. | |
| 071 | ||
| Interruption, overheating sensor G189 | Interruption in wiring and connectors to overheating sensor G189. | Check wiring and connectors using current flow diagram. |
| Overheating sensor G189 defective. | Renew overheating sensor G189. | |
| 072 | ||
| Short circuit, overheating sensor G189 | Short circuit in wiring and connectors to overheating sensor G189. | Check wiring and connectors using current flow diagram. |
| Overheating sensor G189 defective. | Renew overheating sensor G189. | |
| 090 | ||
| 092 | ||
| 093 | ||
| 097 | ||
| Heater control unit J162 defective. | Heater control unit J162 defective. | Perform function test, renew heater control unit J162 if necessary → Chapter. |
| 091 | ||
| External interference voltage | Interference voltage at heater control unit J162. Possible causes:Interference caused by car telephone.Short-distance interference suppressor for coolant fan V7, windscreen wiper motor V or rear window wiper motor V12 defective. | Localise and rectify faults. |
‹ Prev Connecting basic unit VAS 5019/1 and interrogating fault memoryNext › Repairing auxiliary coolant heater -D3W-
Parts & tools for this job For 1990 Volkswagen Transporter
- FLUIDCoolantSearch: Volkswagen coolant antifreeze
- PARTThermostatSearch: Volkswagen Transporter 1990 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.