Workshop Manuals Factory service & repair Volkswagen
01 5-cylinder diesel engine (distributor-type injection pump)02 5-speed manual gearbox 02G, four-wheel drive03 Self-diagnosis for automatic gearbox 01P - from 01.9504 Automatic gearbox 01P - after 01.9505 Running gear: Guide for using trailers06 Wheels and Tyres Guide - General Information07 Running gear: Guide for increasing and decreasing load ratings08 Wheels and Tyres Guide09 Brake systems as of January 199610 Running gear, axles, steering11 Electrical system self-diagnosis12 Electrical system13 Electrical: Communication14 General body repairs, exterior15 General body repairs, interior16 Supplementary heating
Volkswagen Transporter T4 (1990-2003)16 · Supplementary heating
16 · Heating & A/C

Fault table

Make
Volkswagen
Model
Transporter T4
Year
1990–2003
Section
Auxiliary coolant heater D3W › Fault table
Supplementary heatingFault table

Fault table

Note

  • The following table lists all the faults, with the corresponding 3-digit code numbers, that can be detected by heater control unit J162.

Display fault code number and meaningPossible cause of faultRemark / Rectifying fault
000
No malfunction
010
Overvoltage shutdownAlternator C defective.Check alternator C. Current flow diagrams, Electrical fault finding and Fitting locations
011
Undervoltage shutdownVehicle battery flat.Check and charge battery.
Wiring or connectors to heater control unit J162 defective.Check wiring and connectors using current flow diagram.
Alternator C defective.Check alternator C. Current flow diagrams, Electrical fault finding and Fitting locations
012
014Combustion air intake or exhaust system blocked.Carry out visual check.
017Coolant circuit has not been bled properly.Check coolant circuit Rep. Gr.19.
Overheated, shutdown after 3x overheatingQuantity of fuel delivered not ok.Check quantity of fuel delivered → Chapter.
020
Interruption, glow plug for heater Q9Glow plug for heater Q9 defective.Renew glow plug for heater Q9Chapter.
021
Overload at glow plug outputGlow plug for heater Q9 defective.Renew glow plug for heater Q9Chapter.
030
031
032Interruption in wiring from heater control unit J162, contact -T10/2-, via combustion air blower V6 to heater control unit J162, contact -10/1-.Check wiring and connectors using current flow diagram.
Motor for combustion air blower V6 does not rotateCombustion air blower V6 defectiveRenew combustion air blower V6.
047
Short circuit, fuel pump G23Short circuit in wiring from heater control unit J162, contact -T8/4-, via fuel pump G23 to heater control unit J162, contact -T8/3-.Check wiring and connectors using current flow diagram.
Fuel pump G23 defective.Renew fuel pump G23Chapter.
048
Interruption, fuel pump G23Interruption in wiring from heater control unit J162, contact -T8/4-, via fuel pump G23 to heater control unit J162, contact -T8/3-.Check wiring and connectors using current flow diagram.
Fuel pump G23 defective.Renew fuel pump G23Chapter.
051
Flame monitor G64 defectiveFlame monitor G64 defectiveRenew flame monitor G64Chapter.
052
Safety time exceeded, no flameCombustion air intake or exhaust system blocked.Carry out visual check.
Quantity of fuel delivered not ok.Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter.
Glow plug for heater Q9 defective.Renew glow plug for heater Q9Chapter.
054
Flame failure in “HIGH” stageQuantity of fuel delivered not ok.Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter.
056
Flame failure in “LOW” stageQuantity of fuel delivered not ok.Check quantity of fuel delivered → Chapter, renew fuel pump G23 if necessary → Chapter.
060
Interruption, temperature sensor G18Interruption in wiring and connectors to temperature sensor G18.Check wiring and connectors using current flow diagram.
Temperature sensor G18 defective.Renew temperature sensor G18.
061
Short circuit, temperature sensor G18Short circuit in wiring and connectors to temperature sensor G18.Check wiring and connectors using current flow diagram.
064
Interruption, flame monitor G64Interruption in wiring and connectors to flame monitor G64.Check wiring and connectors using current flow diagram.
Flame monitor G64 defectiveRenew flame monitor G64Chapter.
065
Short circuit, flame monitor G64Short circuit in wiring and connectors to flame monitor G64.Check wiring and connectors using current flow diagram.
Flame monitor G64 defectiveRenew flame monitor G64Chapter.
071
Interruption, overheating sensor G189Interruption in wiring and connectors to overheating sensor G189.Check wiring and connectors using current flow diagram.
Overheating sensor G189 defective.Renew overheating sensor G189.
072
Short circuit, overheating sensor G189Short circuit in wiring and connectors to overheating sensor G189.Check wiring and connectors using current flow diagram.
Overheating sensor G189 defective.Renew overheating sensor G189.
090
092
093
097
Heater control unit J162 defective.Heater control unit J162 defective.Perform function test, renew heater control unit J162 if necessary → Chapter.
091
External interference voltageInterference voltage at heater control unit J162. Possible causes:Interference caused by car telephone.Short-distance interference suppressor for coolant fan V7, windscreen wiper motor V or rear window wiper motor V12 defective.Localise and rectify faults.

Parts & tools for this job For 1990 Volkswagen Transporter