Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Bravo Factory Service Manual (2007-2014)22 · Fault diagnosis
22 · Diagnostics

Alarm volumetric surveillance not working

Make
Fiat
Model
Bravo Factory Service Manual
Year
2007–2014
Section
Alarm › Alarm volumetric surveillance not working
Fault diagnosisAlarm volumetric surveillance not working

ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is switched on using the remote control, the system is activated correctly but the volumetric sensors do not intervene

The volumetric sensors are connected to the body computer node via an A-Bus serial line.

The volumetric sensors can be excluded by the customer, using the special button. If there is a failure, the body computer node detects and memorizes the causes of the malfunction.

TEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment to the diagnostic socket and check the following at the body computer node in parameters mode:

- the presence of volumetric sensors in the errors mode:

- that there are no faults with the volumetric sensors.

Move on to Step 2

1. Volumetric sensors excluded manually 2. Volumetric sensors not present

3. Presence of faults

1. Switch on the volumetric sensors

2. Check the conformity of the vehicle.

3. Proceed as instructed by the diagnostic equipment

2ULTRASOUND WAVES CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check that the ultrasound is connected correctly via the A-Bus line to the body computer

See E7015 ALARM

Move on to Step 3Connections not correctRestore the correct connections.
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment to the diagnostic socket and check the following at the body computer node.

In active diagnosis:

the operation of the volumetric modules

End of diagnosis

1. Very defective sensors

2. Body computer defective

1. Replace convergence/bluetooth control panel

2. Replace body computer

Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

Parts & tools for this job For 2007 Fiat Bravo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.