Workshop Manuals Factory service & repair Fiat
01 00 Introduction and technical data02 10 Engine03 18 Clutch04 21 Gearbox and differential05 33 Braking system06 41 Steering07 44 Suspension and wheels08 50 Auxiliary units09 55 Electrical system10 70 Bodywork
Fiat Bravo/Brava (182) Factory Service Manual (1995-2001)01 · 00 Introduction and technical data
01 · General

Fuel system (page 3 of 3)

Make
Fiat
Model
Bravo /Brava (182) Factory Service Manual
Year
1995–2001
Section
Engine
00 Introduction and technical dataFuel system · page 3 of 3
Type of check or adjustment Op. No. Adjust. lever position Rotation speed rpm Supply voltage V Advance check mm Transfer pressure bar Av. capacity per cyl. mm³/cycle Max. disc. btwn 4 flow rates mm³/cycle Operations or checks to be carried out
Anti-stall setting 16 Min 400 12 7 ÷ 9 MIN lever in stop position place a 1.2 mm shim between the max lever/stop
Idle setting 17 Min 400 12 8 ÷ 10 ≤3,0 Remove the anti-stop shim (1.2 mm)
Regulator check 18 Max 2250 12 Make a note of the capacity
Reg. start of int. setting 19 Max 2400 12 23,0 ÷ 25,0
Max no load check 20 Max 2800 12 ≤10 No supply above 11 mm³/cycle
Full load advance check 21 Max 2800 12 5,6 ÷ 6,2
Regulator check 22 Max 2250 12 Check that the capacity is ≥ that measured at point 18
Stop the bench for at least 10 secs and until the internal pressure has gone down to 0 bar
Delay during starting check 23 Max 0 12 -1,9 ÷ 2,6
Enrichment capacity 24 Max 100 12 32,0 ÷ 48,0
End of enrichment 25 Max 110 ÷ 270 12 0 ÷ 0,4 Accelerator lever released
Max. capacity check 26 Max 270 12 ≤35,0
Max. capacity check 27 Max 1350 12 31,0 ÷ 35,0
Full load advance check 28 Max 1350 12 0,6 ÷ 1,8
Max. capacity check 29 Max 2200 12 35,5 ÷ 39,5
Check and/or adjust the length of the cold advance control rod at 65 mm and reconnect it to the valve lever
Advance when cold check 30 Min 400 12 1,3 ÷ 1,7 Insert a 4 mm shim between the Min lever and stop
Advance when cold check 31 Min 400 12 0 ÷ 0,1 Insert a 2 mm shim between the Min lever and stop
Determine "V" outlet internal stage 32 Apply a pressure of 80 bar simultaneously to the 4 high pressure outlets and 2 bar (compressed air) to the diesel inlet union. Fit the special instrument and rotate the pump shaft with a torque of 0.16 N/m until a hardening is obtained, then measure the distance on the dial gauge
Determine engine timing 33 Add 4 mm to the figure measured (point 32) and note the resulting value on the introduction adjustment access hole sealing cap. This value should be set for the engine when cylinder no. 1 is at fDC

Parts & tools for this job For 1995 Fiat Bravo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.