Workshop Manuals Factory service & repair Fiat
01 00 Introduction and technical data02 10 Engine03 18 Clutch04 21 Gearbox and differential05 33 Braking system06 41 Steering07 44 Suspension and wheels08 50 Auxiliary units09 55 Electrical system10 70 Bodywork
Fiat Bravo/Brava (182) Factory Service Manual (1995-2001)02 · 10 Engine
02 · Engine

Removing-refitting injection pump (page 3 of 3)

Make
Fiat
Model
Bravo /Brava (182) Factory Service Manual
Year
1995–2001
Section
Fuel system (1910 TD 100)
10 EngineRemoving-refitting injection pump · page 3 of 3
Diagram showing the injection pump drive pulley with service bolts and fixing bolts indicated by callout numbers 1 and 2
Diagram showing the diesel supply and return pipes connected to the filter and pump area, with arrows indicating connection points


  1. Stop the rotation of the injection pump drive pulley by tightening the two service bolts (1) in the special openings in the pump support, then undo the bolts (2) fixing the pulley, undo the bolts (1) and remove the pulley.
  2. Acting at the points shown, disconnect the diesel supply pipes from the filter to the pump, the diesel return pipes from the pump to the tank and the diesel return pipes from the injectors to the pump.
  3. Undo the fixing bolts and remove the sound insulation shield.
  4. Disconnect the electrical connections, disconnect the diesel supply pipe between the tank and the filter, undo the fixing nuts and remove the diesel filter.
Diagram showing the sound insulation shield location on the engine block
Diagram showing the diesel filter with arrows pointing to electrical connections, supply pipe, and fixing nuts

Parts & tools for this job For 1995 Fiat Bravo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.