Refitting
- Make
- Fiat
- Model
- Seicento Factory Service Manual
- Year
- 1998–2010
- Section
- Heater › Refitting
Name
Climate control fan control
Connector H81
- Take out the switch control group lighting bulb holder.
- Remove heater controls support from the bracket.
Refitting
- Assemble heater controls support on the heater box bracket.
- Insert switch control group lighting bulb holder.
- Connect the climate control fan control electrical connection
Name
Climate control fan control
Connector H81
- Connect the air intake/recirculation flap control cable.
- Connect the air distribution flap control cable.
Note: After connecting the air intake/recirculation and air distribution flap control cables, check that with the knobs at the end of stroke the flaps shut off the air completely.
- Connect the heater cock control cable.
Note: After connecting the heater cock control cable, check that with the knob in cold air and maximum air heating positions the heater cock is fully closed and fully open respectively.
5020B38 - AIR DISTRIBUTION FLAP CONTROL - R.R.
- To release/engage the air distribution flap control from the heater controls support see Op. 5020B14 Heater controls SUPPORT - R.R. with heater group removed.
- To release/engage the air distribution flap control from the heater box see Op. 5020A24 HEATER BOX - Disassembly e Reassembly at the bench.
5020B42 - AIR MIXING FLAP CONTROL - R.R.
- To release/engage the air mixing flap control from the heater controls support see Op. 5020B14 Heater controls SUPPORT - R.R. with heater group removed.
- To release/engage the air mixing flap control from the heater box see Op. 5020A24 HEATER BOX - Disassembly e Reassembly at the bench.