Climate control not cooling
- Make
- Lancia
- Model
- Thesis Factory Service Manual
- Year
- 2002–2009
- Section
- Climate control › Climate control not cooling
CLIMATE CONTROL NOT COOLING
The fan works normally and sends air to the passenger compartment according to the pre-set flows bu the air remains at the outside temperature and is not cooled.
The enablement of the engagement of the refrigerant circuit is controlled by both the climate control system control unit and the engine management control unit. Therefore if the climate control system is not cooling in certain conditions, this is correct.
| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | ||
|---|---|---|---|---|
| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the condition of the compressor drive belt | Move on to Step | Belt deteriorated | Replace the belt See in Op. 1092G10 Engine components single drive BELT - R.R. | |
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
With the tester (Examiner or other instrument) connected, check the CAN network information for:
| Move on to Step | 1. Presence of faults | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Error detected in the climate control system control unit | Move on to Step | |||
| 3. Error detected in the engine management control unit | Move on to Step | |||
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:
| Move on to Step | 1. Presence of faults | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Parameters not plausible | 2. Continue following the instructions for the diagnostic equipment | |||
| 3. No communication between climate control system control unit | 3. Restore connection between the climate control unit and diagnostic connector (Wiring Diagram ) E6020 AIR CONDITIONING | |||
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| 2.4 20 V,2.0 TB,3.0 V6 | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:
| Move on to Step | 1. Presence of faults | 1.Continue following the instructions for the diagnostic equipment |
| 2. Parameters not plausible | 2. Continue following the instructions for the diagnostic equipment | |||
| 3. Climate control circuit pressure not correct | Move on to Step | |||
| 4. No dialogue with the engine management control unit | 4. Restore connection between the climate control unit and diagnostic connector (Wiring Diagram ) E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | |||
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| 2.4 JTD 10V | Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:
| Move on to Step | 1. Presence of faults | 1. Continue following the instructions for the diagnostic equipment |
| 2. Parameters not plausible | 2. Continue following the instructions for the diagnostic equipment | |||
| 3. Climate control circuit pressure not correct | Move on to Step | |||
| 4. No dialogue with the engine management control unit | 4. Restore connection between the climate control unit and diagnostic connector (Wiring Diagram ) E5050 DIESEL ENGINE ELECTRONIC MANAGEMENT | |||
| 4 | SYSTEM PRESSURE CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the system pressure | Move on to Step | Pressure not correct | Eliminate leaks and top up climate control system to correct level See in Op. 5040A10 Air conditioning coolant circuit - Drying and Repressurizing | |
| 5 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check the following at the climate control node:
| Move on to Step | 1. relay does not come on and coupling not activated | Move on to Step | |
| 2. relay comes on and coupling not activated | Move on to Step | |||
| 6 | RELAY ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the continuity of the relay operating circuit | Move on to Step | 1. Connections not correct | 1. Restore the connections (Wiring Diagram ) E6021 COMPRESSOR ENGAGEMENT | |
| 2. Relay faulty | 2. Replace the relay | |||
| 7 | COMPRESSOR ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the continuity of the compressor power circuit | Move on to Step | 1. Connections not correct | 1. Restore the connections (Wiring Diagram ) E6021 COMPRESSOR ENGAGEMENT | |
| 2. Electro-magnet coupling faulty | 2. Replace the compressor complete with coupling | |||
| 8 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | Fault persists | Replace the climate control system control unit | ||
Parts & tools for this job For 2002 Lancia Thesis
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Lancia Thesis 2002 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.