Workshop Manuals Factory service & repair Lancia
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Service news bulletins24 Special tools
Lancia Thesis Factory Service Manual (2002-2009)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation not working

Make
Lancia
Model
Thesis Factory Service Manual
Year
2002–2009
Section
Climate control › Climate control recirculation not working
Fault diagnosisClimate control recirculation not working

CLIMATE CONTROL RECIRCULATION NOT WORKING

The climate control recirculation does not work in any conditions (manual/automatic)

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket.Check that there are no faults in the climate control system control unitMove on to Step1. Error detected in the control unit1. Continue following the instructions for the diagnostic equipment
2. No communication with the control unit

2. Restore connection between the climate control unit and diagnostic connector

(Wiring Diagram ) E6020 AIR CONDITIONING

2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis for the recirculation motorMove on to StepRecirculation motor faultyMove on to Step
3MOTOR ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the recirculation motor electrical circuit

(Wiring Diagram ) E6020 AIR CONDITIONING

Move on to Step1. Recirculation motor connection faulty

1. Restore the correct connection

(Wiring Diagram ) E6020 AIR CONDITIONING

2. Connections correct, flap/motor unit faulty

2. Check that the flap moves freely, if necessary, replace the recirculation motor

See in Op. 5040D88 MOTOR for ANY COMPARTMENT - R.R. with air conditioning casing removed

4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persists

Replace the climate control system control unit

See in Op. 5040D18 Air conditioning CONTROL UNIT - R.R.

Parts & tools for this job For 2002 Lancia Thesis

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.