01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Service news bulletins24 Special tools
Lancia Thesis Factory Service Manual (2002-2009)22 · Fault diagnosis
22 · Diagnostics

Climate control not heating

Make
Lancia
Model
Thesis Factory Service Manual
Year
2002–2009
Section
Climate control › Climate control not heating
Fault diagnosisClimate control not heating

CLIMATE CONTROL NOT HEATING

The climate control works properly and sends air to both the left and right sides of the passenger compartments according to the pre-set flows, but this air does not ensure the heating required.

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Using the diagnostic equipment (Examiner or other instruments) connected, check the following information at the CAN network:

  • no control unit not activated;
  • that there are no faulty control units;
  • no control unit with faulty CAN line
Move on to Step1. Presence of faults1. Continue following the instructions for the diagnostic equipment
2. Climate control system control unit errorMove on to Step
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:

  • for faults in the climate control system control unit
Move on to Step1. Error detected in the control unit1. Continue following the instructions for the diagnostic equipment
2. No communication with the control unit

2. Restore the connection between the climate control system control unit and the diagnostic connector

(Wiring Diagram ) E6020 AIR CONDITIONING

3ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis of the mixing motorsMove on to Stepmixing motor(s) not workingMove on to Step
4CHECK ELECTRICAL CIRCUITALL OKPROBLEMS ENCOUNTEREDACTION
Check the condition of the electrical circuit for the mixing motorsMove on to Step1. Mixing motor(s) electrical circuit faulty1. Restore the connections (see Wiring Diagram E6020)
2. Connections correct, right motor defective

2. Replace the motor

See in Op. 5040D86 air conditioner right air mixture flap control motor - r r

3. Connections correct, left motor defective

3. Replace the motor

See in Op. 5040D84 air conditioner left hand air mixer flap control motor - r r

5HEATER HYDRAULIC CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check:

  • that there is no air in the heater circuit
  • the seal of the supply and return pipes
Move on to Step1. Air in the circuit1. Bleed the heater circuit
2. No pipe seal

2. 1. Renew the seal, if necessary, replace the pipe

See in Op. 5040A50 PIPE from compressor to air conditioner condenser - R and R

6HEATER RADIATOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the efficiency of the heater radiatorMove on to StepRadiator dirty or obstructed

Clean the radiator, if necessary, replace it

See in Op. 5040C50 Air conditioning HEATER RADIATOR - R.R.

7CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present

Parts & tools for this job For 2002 Lancia Thesis

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.