Functional description
The Body Computer M1 receives as input the signals coming from the aerial-receiver P93, which is connected to pins 21 and 31 of connector A.
Via the CAN line, the Body Computer M1 is connected to the controls unit on the door H44.
The controls unit on the door H44 is supplied - pin 24 of connector B - from the line protected by the fuse F39 of the unit under the dashboard B2.
The unit H44 receives as input the signal from the release button, located in the controls unit H12, at pin 3 of connector B.
According to the control logic described above, the unit H44 sends a command from pin 6 of connector A, which energizes the boot opening relay J56 which, supplied by the line protected by shunt fuse B60, controls the operation of the boot lock geared motor N57.
Functional description
According to the control logic described above, the unit H44 sends a command from pin 6 of connector A, which energizes the boot opening relay J56 which, supplied by the line protected by fuse F60 of the fuse box B98, controls the operation of the boot lock motor N57.