Workshop Manuals Factory service & repair Fiat
01 00 Introduction and technical data02 10 Engine03 18 Clutch04 21 Gearbox and differential05 33 Braking system06 41 Steering07 44 Suspension and wheels08 50 Auxiliary units09 55 Electrical system10 70 Bodywork
Fiat Bravo/Brava (182) Factory Service Manual (1995-2001)02 · 10 Engine
02 · Engine

Adjusting butterfly valve opening control

Make
Fiat
Model
Bravo /Brava (182) Factory Service Manual
Year
1995–2001
Section
Fuel system (1370 12v) › Adjusting butterfly valve opening control
10 EngineAdjusting butterfly valve opening control

ADJUSTING BUTTERFLY VALVE OPENING CONTROL

Diagram showing the butterfly valve opening linkage with numbered callouts (1-7) indicating components such as levers, links, a block, and a gauge, along with a specified clearance dimension of 0.2÷0.5mm.

The butterfly valve opening linkage must be adjusted properly for the Monomotronic injection system to work properly.

Check that block (3) is fully home with link (1) disconnected from lever (2). Under these conditions the accelerator control cable should never be taut or excessively slack so that accelerator pedal free travel is taken up. If pedal shows free travel, adjust accelerator control cable nut and lock-nut.

Connect link (1) to head of lever (2) and warm up engine.

With accelerator pedal released (butterfly valve closed) check clearance between levers (2) and (4) is 0.2 - 0.5 mm.

If the above clearance is not as specified, loosen nuts (5) and (6) and tighten/loosen gauge (7) on link (1).

After adjustment, check that butterfly valve is fully open with accelerator pedal pressed fully down.

Parts & tools for this job For 1995 Fiat Bravo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.