Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Grande Punto Factory Service Manual (2005-2012)08 · Engine
08 · Engine

Exhaust fumes - check with opacimeter

Make
Fiat
Model
Grande Punto Factory Service Manual
Year
2005–2012
Section
Emission control system › Exhaust fumes - check with opacimeter
EngineExhaust fumes - check with opacimeter

EXHAUST FUMES - CHECK WITH OPACIMETER

Operation 1080A20 · EMISSION CHECKS AND ADJUSTMENTS

1.9 Multijet

- Start the car and let it warm up until the radiator cooling fan has come on twice.

Leave as little time as possible before starting the test once the engine is warm and avoid leaving the engine to idle for long periods.

Check that the probe diameter is at least 0.22 times the diameter of the exhaust pipe.

Ensure that the exhaust gas intake fittings do not allow leaks.

- Position the fume meter measurement probe in the end of the exhaust pipe, ensuring that its end is positioned in a pipe section where the gas flow is evenly distributed.

- If necessary, to meet the above requirements, apply an extension to the exhaust pipe so that the coupling to the exhaust pipe is sealed and the end of the probe is positioned in a long straight section towards the engine that is at least six times the tailpipe diameter and at least three times the tailpipe diameter downstream.

Check that the probe intake pipe from the tailpipe to the fume meter is on an ascending gradient without any sharply angled joints.

Ensure the counterpressure at the probe is as specified and does not exceed 7.5 mbar during the test.

- With the engine running at idle speed, place the gearbox in neutral and release the clutch pedal.

- Position the fume meter so that exhaust gas can be drawn off.

- Take the reading shown by the fume meter pointer.

- As the engine is idling, operate the accelerator pedal quickly but smoothly until the engine is running at maximum rpm and the regulator cuts in.

- Record and note down the maximum fume level indicated by the fume meter during acceleration without taking values during the release stage into account.

- Once the maximum rotation speed has been achieved, release the accelerator control until the engine resumes idling.

- Check that the fume meter pointer returns to the position measured previously at idle speed.

- Repeat the above operations at least six times until the fume readings stabilise.

The readings may be considered stable when they are within a band that is 1.25 m-1 wide for four consecutive readings and not in decreasing order.

- The fume value to be considered is the arithmetic mean of the four stabilised values.

- Check that the fume level imeets the required value stamped on the vehicle marking summary plate located in the engine compartment and indicated in the following table.

MeasurementValueValidity
Exhaust fumes1.25 m-11.9 Multijet
MeasurementValueValidity
Exhaust fumes0.54 m-1

1.9 Multijet

with DPF

1.3 Multijet

- Start the car and let it warm up until the radiator cooling fan has come on twice.

Leave as little time as possible before starting the test once the engine is warm and avoid leaving the engine to idle for long periods.

Check that the probe diameter is at least 0.22 times the diameter of the exhaust pipe.

Ensure that the exhaust gas intake fittings do not allow leaks.

- Position the fume meter measurement probe in the end of the exhaust pipe, ensuring that its end is positioned in a pipe section where the gas flow is evenly distributed.

- If necessary, to meet the above requirements, apply an extension to the exhaust pipe so that the coupling to the exhaust pipe is sealed and the end of the probe is positioned in a long straight section towards the engine that is at least six times the tailpipe diameter and at least three times the tailpipe diameter downstream.

Check that the probe intake pipe from the tailpipe to the fume meter is on an ascending gradient without any sharply angled joints.

Ensure the counterpressure at the probe is as specified and does not exceed 7.5 mbar during the test.

- With the engine running at idle speed, place the gearbox in neutral and release the clutch pedal.

- Position the fume meter so that exhaust gas can be drawn off.

- Take the reading shown by the fume meter pointer.

- As the engine is idling, operate the accelerator pedal quickly but smoothly until the engine is running at maximum rpm and the regulator cuts in.

- Record and note down the maximum fume level indicated by the fume meter during acceleration without taking values during the release stage into account.

- Once the maximum rotation speed has been achieved, release the accelerator control until the engine resumes idling.

- Check that the fume meter pointer returns to the position measured previously at idle speed.

- Repeat the above operations at least six times until the fume readings stabilise.

The readings may be considered stable when they are within a band that is 1.53 m-1 wide for the 75 bhp version, 1.34 m-1 for the 90 bhp version and not in decreasing order.

- The fume value to be considered is the arithmetic mean of the four stabilised values.

- Check that the fume level imeets the required value stamped on the vehicle marking summary plate located in the engine compartment and indicated in the following table.

MeasurementValueValidity
Exhaust fumes1.53 m-11.3 Multijet 75bhp
MeasurementValueValidity
Exhaust fumes1.34 m-11.3 Multijet 90CV
MeasurementValueValidity
Exhaust fumes0.51 m-1

1.3 Multijet

90CV

with DPF

Parts & tools for this job For 2005 Fiat Grande Punto

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.