CLIMATE CONTROL AIR FLOW IRREGULAR
The flow of air sent by the fan in the passenger compartment using the manual speed control is not sufficient; it does not correspond to the speed set.
| 1 | AIR DUCTS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
| Check that the air ducts are intact and the vents are not blocked and are correctly positioned in the opening. | Move on to Step 2 | 1.Air ducts or vents obstructed | 1.Restore the operation of the air ducts and the vents removing any material causing an obstruction. | |
| 2.The flow of air does not correspond to the distribution selected | 2.Move on to Step 5 | |||
| 2 | CHECK ON CORRECT OPERATION OF MAXIMUM SPEED RELAY | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check whether the electrical wiring connections are loose, disconnect visually inspecting for any damage at the connector contacts. Reconnect the connection to the resistor. Check the operation of the fan at the maximum speed: if it only works at the maximum speed, the relay is broken. Check whether the resistor is broken by checking the electrical continuity in accordance with the test. See Test 5040CF SEQUENTIAL PROCEDURE FOR CHECKING OPERATION OF AIR CONDITIONING FAN RESISTOR | Move on to Step 3 | 1.Electrical connections loose or damaged. | 1. Renew the electrical connections | |
| 2.Relay broken. | 2.Replace the ceramic resistor | |||
| 3.Resistance values faulty | 3.Replace the ceramic resistor | |||
| 3 | CHECK ON CORRECT OPERATION OF SPEED SELECTOR AT THE CLIMATE CONTROL SYSTEM CONTROL UNIT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check whether the electrical wiring connections are loose, disconnect visually inspecting for any damage to the connector contacts. Reconnect the connection to the selector on the climate control system control unit. Check whether the selector at the control unit is broken by measuring the electrical continuity in accordance with the test See Test 5040DF SEQUENTIAL PROCEDURE FOR CHECKING OPERATION OF AIR CONDITIONING FAN | Move on to Step 4 | 1.Electrical connections loose or damaged. | 1. Renew the electrical connections | |
| 2.Fan not working. | 2.Replace the speed selector knob Op. 5040D23 KNOB (ONE) FOR ANY OF THE AIR CONDITIONING CONTROLS - R.R. | |||
| 3.Power supply to the relays not correct. | 3.Replace the climate control system control unit Op. 5040D17 CONTROL UNIT WITH MANUAL AIR CONDITIONER KNOBS AND BUTTONS R R | |||
| 4 | CHECK ON CORRECT OPERATION OF FAN | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check whether the electrical wiring connections are loose Disconnect, visually inspecting for any damage at the connector contacts. Reconnect the connection at the engine mounting. Check that it turns at all speeds when activated by the switch. If it does not rotate at the maximum speed, check the maximum fan speed relay. | Move on to Step 5 | 1.Electrical connections loose or damaged | 1. Renew the electrical connections | |
| 2.Fan not working. | 2.Replace the fan | |||
| 5 | CHECK ON CORRECT OPERATION OF FAN MAXIMUM SPEED OPERATING RELAYS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check whether the electrical wiring connections are loose. Disconnect visually inspecting for any damage to the connector contacts. Reconnect the connection to the relay. Check that the relay is working properly by providing it with a direct 12 V supply. | Move on to Step 6 | 1.Electrical connections loose or damaged | 1. Renew the electrical connections | |
| 2.Maximum speed operating relay not working | 2.Replace the maximum speed operating relay | |||
| 6 | CHECK ON CORRECT OPERATION OF DISTRIBUTION ACTUATOR KINEMATIC COMPONENTS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Visually inspect that the mixture actuator is working properly from the climate control system control unit temperature control knob. Check whether the control on the control unit is interrupted when measuring the electrical continuity in the test. | End of diagnosis | 1.Incorrect operation of actuator | 1.Move on to Step 7 | |
| 2. Physical impediment to flap rotation | 2.Replace the control unit | |||
| 3.Incorrect operation of the control actuator on the climate control unit. | 3.Replace the climate control system control unit Op. 5040D17 CONTROL UNIT WITH MANUAL AIR CONDITIONER KNOBS AND BUTTONS R R | |||
| 7 | CHECK ON CORRECT OPERATION OF DISTRUBITION ACTUATOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check that the distrubition actuator is working properly by carrying out the test See Test 5040DH SEQUENTIAL PROCEDURE FOR CHECKING OPERATION OF MIXTURE AND DISTRIBUTION ACTUATORS | End of diagnosis | 1.Actuator not working correctly. | 1.Replace the timing actuator Op. 5040D63 AIR DISTRIBUTION FLAP CONTROL ACTUATORS- R.R. WITH AIR CONDITIONING CASING REMOVED | |
| 2.Resistance values incorrect. | 2.Replace the timing actuator Op. 5040D63 AIR DISTRIBUTION FLAP CONTROL ACTUATORS- R.R. WITH AIR CONDITIONING CASING REMOVED |
The flow of air sent by the fan in the passenger compartment using the manual speed control is not sufficient; it does not correspond to the speed set.
| 1 | CHECK ON OPERATION OF FAN BY CLIMATE CONTROL SYSTEM CONTROL UNIT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
| With the engine started, set the climate control system control unit to the AUTO position, adjust the temperature to 22 °C, place the recirculation at the outside air intake and the distribution to the front position. Adjust the fan button (+ side) gradually increasing the speed set and then decrease the speed using the button (- side), thereby checking the effect of the air flow rate variation. | End of diagnosis | There is no variation in the air flow rate. | Move on to Step 2 | |
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Connect the diagnostic equipment and check:
| Move on to Step 3 | 1.Error at passenger compartment fan. | 1.Move on to Step 5 | |
| 2.Fan operating module error. | 2.Move on to Step 5 | |||
| 3.Error at the distribution actuator. | 3.Move on to Step 6 | |||
| 4.Short circuit error. | 4.Move on to Step 4 | |||
| 3 | CHECK ON AIR DUCTS AND POLLEN FILTER | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the air ducts are intact and the vents are not blocked and are correctly positioned in the opening. Check that the pollen filter is not obstucted. | Move on to Step 4 | 1.Air ducts or vents obstructed. | 1.Restore the operation of the air ducts and the vents removing any material causing an obstruction. | |
| 2.Pollen filter obstructed. | 2.Replace the pollen filter Op. 5010B09 PURIFYING (POLLEN) FILTER FILTER ELEMENT - REPLACE | |||
| 4 | CHECK ON CLIMATE CONTROL NODE ELECTRICAL CONNECTIONS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| With the engine switched off, remove the control from the dashboard support and disconnect the cables connector from the control unit visually inspecting for any damage at the connector contacts and reconnect it correctly for check for any false contacts. | Move on to Step 5 | Electrical connections loose or damaged. | Renew the electrical connections | |
| 5 | CHECK ON ELECTRICAL CONNECTIONS AND FAN OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check whether the electrical wiring connections are loose. Disconnect/reconnect the connection to the engine mounting. Disconnect the connector and connect it to a feeder. In these conditions the engine should turn at the maximum speed indicating that the operating module is not working | Move on to Step 6 | 1.Electrical connections loose | Renew the electrical connections | |
| 2.The fan does not work. | 2.Replace the fan | |||
| 3.The operating module does not work. | 3.Replace the fan operating module | |||
| 6 | CHECK ON CORRECT OPERATION OF DISTRIBUTION ACTUATOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check whether the electrical wiring connections are loose. Disconnect visually inspecting for any damage at the connector contacts and reconnect the connection to the engine mounting. If it persists, before replacing the actuator, check its operation by manually activating the function that the actuator should carry out. With the engine running, switch on the fan at maximum speed. Place the flaps in the various distribution positions via the control/control unit (manually). Check the air flow in the passenger compartment with your hand at the vents. | End of diagnosis | 1.Electrical connections loose or damaged. | Renew the electrical connections | |
| 2.There is no air flow into the passenger compartment from the vents. | 2.Move on to Step 7 | |||
| 7 | CHECK FOR IMPEDIMENTS TO THE ROTATION OF THE DISTIRUBTION ACTUATOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Remove the actuator and check using the control unit control that the actuator turns checking for mechanical impediments to its rotation. | End of diagnosis | 1.The actuator does not turn. | 1.Replace the timing actuator Op. 5040D63 AIR DISTRIBUTION FLAP CONTROL ACTUATORS- R.R. WITH AIR CONDITIONING CASING REMOVED | |
| 2.Kinematic components or flaps broken/stuck | 2.Replace the components that is faulty. |