Climate control not heating
- Make
- Fiat
- Model
- Croma Factory Service Manual
- Year
- 2005–2010
- Section
- Climate control › Climate control not heating
CLIMATE CONTROL NOT HEATING
The climate control is working properly and sends air according to the preset flows but this air does not guarantee the required heating.
| PRELIMINARY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
|---|---|---|---|---|
| 0 | Check that the engine coolant level is within the preset levels and that the refrigerant fluid circulates correctly in the system | Move on to Step 1 | 1.Engine coolant level too low. | 1,Restore the correct level Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE check for leaks |
| 2.Coolant does not circulate correctly: thermostat valve operationg incorrectly. | 2.Perform diagnosis | |||
| CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 1 | With the engine on and the compressor off, in manual mode with the temperature knob at the maximum hot HI position. Also set the recirculation button to the closed position and set the fan speed to 6 bars (display) and the distribution to front ventilation. Use the diagnostic tester to check that the engine temperature reaches at least 70 °C. Check that the air temperature at the front distribution outlet is greater than 60 °C. | End of diagnosis | The temperature of the air coming out of the vents is not as desired. | Move on to Step 2 |
| CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 1 | With the engine on and the compressor off, in manual mode with the temperature knob at the maximum hot HI position. Also set the recirculation button to the closed position and set the fan speed to the 3rd setting and the distribution to front ventilation. Use the diagnostic tester to check that the engine temperature reaches at least 70 °C. Check that the air temperature at the front distribution outlet is greater than 60 °C. | End of diagnosis | The temperature of the air coming out of the vents is not as desired. | Move on to Step 2 |
| CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 2 | Connect the diagnostic equipment and check:
| End of diagnosis | 1. Short circuit error at the air mixing actuators | 1.Move on to Step 3 |
| 2. Error in the engine temperature sensor | 2. Continue as instructed by the diagnostic equipment | |||
| CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 2 | Connect the Examiner diagnostic equipment and check that there are no errors in the engine temperature sensor | Move on to Step 5 | Error in the engine temperature sensor | Continue as described by the diagnostic equipment |
| ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 3 | Check whether the electrical wiring connections are loose: Disconnect and check for damage in the connector contacts/reconnect the connection to the actuator. Check the continuity/insulation of the electrical connection:
| Move on to Step 4 | 1. Electrical connections loose or damaged. | 1. Renew the electrical connections |
| 2. Electrical connection broken or not insulated. | 2. Restore the continuity/insulation of the electrical connection | |||
| CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 4 | Check for persistent errors in the air mixer actuators | End of diagnosis | Air mixing actuator error | Move on to Step 5 |
| CHECK THE CORRECT OPERATION OF THE MIXER ACTUATOR DRIVE CHAIN | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 5 | Visually check the correct operation of the mixer actuator from the climate control unit temperature control knob. Check whether the control on the control unit is interrupted by checking the electrical continuity in accordance with the test. See Test 5040DH SEQUENTIAL PROCEDURE FOR CHECKING OPERATION OF MIXTURE AND DISTRIBUTION ACTUATORS | Move on to Step 6 | 1. Incorrect operation of actuator | 1. Replace the mixer actuator |
| 2. Physical impediment to flap rotation | 2. Replace the control unit | |||
| 3. Incorrect operation of the control actuator on the climate control unit | 3. Replace the climate control system control unit | |||
| CHECK THE CORRECT OPERATION OF THE MIXER ACTUATOR DRIVE CHAIN | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 5 | Visually check the correct operation of the mixer actuator from the climate control unit temperature control knob. Check whether the control on the control unit is interrupted by checking the electrical continuity in accordance with the test. See Test 5040DH SEQUENTIAL PROCEDURE FOR CHECKING OPERATION OF MIXTURE AND DISTRIBUTION ACTUATORS | Move on to Step 6 | 1. Incorrect operation of actuator | 1. Replace the mixer actuator |
| 2. Physical impediment to flap rotation | 2. Replace the control unit | |||
| 3. Incorrect operation of the control actuator on the climate control unit | 3. Replace the climate control system control unit | |||
| AIR MIXTURE ACTUATOR FLAP CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 6 | Check that the air mixture actuator flap completes its travel without any impediment | End of diagnosis | 1. Flap travel incomplete | 1. Free the air mixer actuator flap from the impediment |
| 2. Flap damaged | 2. Replace the flap | |||
| 3. Drive chain/gears damaged. | 3. Restore the correct drive chain. |
Parts & tools for this job For 2005 Fiat Croma
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Fiat Croma 2005 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.