01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation (automatic mode) not working

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Climate control › Climate control recirculation (automatic mode) not working
Fault diagnosisClimate control recirculation (automatic mode) not working

CLIMATE CONTROL RECIRCULATION (AUTOMATIC MODE) NOT WORKING

AUTOMATIC AIR CONDITIONING

For vehicles with AQS sensors only, the recirculation is not closed automatically if there is pollution (CO, NO2 toxic gases only). The automatic climate control is on the dual zone version only.

CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODEALL OKPROBLEMS ENCOUNTEREDACTION
1

With the engine started up, set the climate control system control unit to the AUTO position, adjust the temperature knob to 22°C, set the fan speed to 8 bars, then press the recirculation button (check that the symbol appears on the display). Check that the air flow rate varies during the opening/closing of the flap. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake.

"When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up".

Move on to Step 21.The recirculation symbol does not appear on the display1. Move on to Step 4
2.The recirculation symbol appears on the display (but the recirculation does not work).2. Move on to Step 2
CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
2

Connect the Examiner diagnostic equipment and check:

  • that there are no errors at the air recirculation actuator;
  • that there are no faults in the AQS sensor.
Move on to Step 61. Errors at the recirculation actuator.1. Move on to Step 3
2. Errors in the AQS sensor.2. Move on to Step 4
CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
3

Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,

  • that the air recirculation is working properly;
  • that all the LEDs and graphic LCD symbols in the display come on.
Move on to Step 61.Air recirculation actuator not working1.Move on to Step 4
2. The LED with the recirculation symbol does not light up.

2. Replace the climate control system control unit

Op. 5040D18 AIR CONDITIONING CONTROL UNIT - R.R.

CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
4
  • that the recirculation flap is working properly in automatic mode by carrying out the "Pollutiono sensor test".

If the result is negative, carry out the test.

See Test 5040DD CHECK ON POLLUTION SENSOR SIGNAL (AQS)

End of diagnosis1.AQS sensor not working

1.Replace AQS sensor

Op. 5010D72 AIR QUALITY SENSOR - R.R. FOLLOWING ELECTRICAL CIRCUIT CHECK

2. Wiring faulty.2. Repair the wiring
ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
5

Check whether the electrical wiring connections are loose.

Remove the control unit from the dashboard mounting, disconnect the cable connector from the control unit visually inspecting for any damage to the connector and connect it correctly to check for any false contacts.

Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator.

Move on to Step 5Electrical wiring connections loose or damaged.Restore the correct wiring connections.
CHECK ON CORRECT OPERATION OF RECIRCULATION ACTUATORALL OKPROBLEMS ENCOUNTEREDACTION
6

Then proceed as follows: with the vehicle running, switch on the air recirculation function manually with the fan at the maximum speed. If the actuator works and the flap is operated, check by feeling that the air flwo varies when it is moved. Deactivate the function by returning the actuator to its original position. Identify the grille on the vehicle for the air intake casing and check the air intake between the recirculation and the outside air and viceversa by feeling by hand. If the result of the check is positive, do not replace the actuator. If there are further doubts as to the operation of the actuator, it is possible to carry out the check following the instructions described below if the air intake casing is easily accessible.

See Test 5040DE CHECK ON OPERATION OF RECIRCULATION ACTUATORS

Move on to Step 7Incorrect operation of recirculation actuator.

Replace the recirculation actuator

Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R

RECIRCULATION ACTUATOR FLAP CHECKALL OKPROBLEMS ENCOUNTEREDACTION
7Visually inspect that the air recirculation actuator flap completes its travel without any hinderanceEnd of diagnosis1. Flap travel incomplete.1.Free from air recirculation actuator flap from the impediment.
2. Flap damaged.2.Replace the flap.
3. Kinematic mechanism damaged.3.Repair kinematic mechanism.