Climate control recirculation (automatic mode) not working
- Make
- Fiat
- Model
- Croma Factory Service Manual
- Year
- 2005–2010
- Section
- Climate control › Climate control recirculation (automatic mode) not working
CLIMATE CONTROL RECIRCULATION (AUTOMATIC MODE) NOT WORKING
For vehicles with AQS sensors only, the recirculation is not closed automatically if there is pollution (CO, NO2 toxic gases only). The automatic climate control is on the dual zone version only.
| CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODE | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
|---|---|---|---|---|
| 1 | With the engine started up, set the climate control system control unit to the AUTO position, adjust the temperature knob to 22°C, set the fan speed to 8 bars, then press the recirculation button (check that the symbol appears on the display). Check that the air flow rate varies during the opening/closing of the flap. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake. "When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up". | Move on to Step 2 | 1.The recirculation symbol does not appear on the display | 1. Move on to Step 4 |
| 2.The recirculation symbol appears on the display (but the recirculation does not work). | 2. Move on to Step 2 | |||
| CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 2 | Connect the Examiner diagnostic equipment and check:
| Move on to Step 6 | 1. Errors at the recirculation actuator. | 1. Move on to Step 3 |
| 2. Errors in the AQS sensor. | 2. Move on to Step 4 | |||
| CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 3 | Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,
| Move on to Step 6 | 1.Air recirculation actuator not working | 1.Move on to Step 4 |
| 2. The LED with the recirculation symbol does not light up. | 2. Replace the climate control system control unit | |||
| CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 4 |
If the result is negative, carry out the test. | End of diagnosis | 1.AQS sensor not working | 1.Replace AQS sensor Op. 5010D72 AIR QUALITY SENSOR - R.R. FOLLOWING ELECTRICAL CIRCUIT CHECK |
| 2. Wiring faulty. | 2. Repair the wiring | |||
| ELECTRICAL CONNECTIONS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 5 | Check whether the electrical wiring connections are loose. Remove the control unit from the dashboard mounting, disconnect the cable connector from the control unit visually inspecting for any damage to the connector and connect it correctly to check for any false contacts. Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator. | Move on to Step 5 | Electrical wiring connections loose or damaged. | Restore the correct wiring connections. |
| CHECK ON CORRECT OPERATION OF RECIRCULATION ACTUATOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 6 | Then proceed as follows: with the vehicle running, switch on the air recirculation function manually with the fan at the maximum speed. If the actuator works and the flap is operated, check by feeling that the air flwo varies when it is moved. Deactivate the function by returning the actuator to its original position. Identify the grille on the vehicle for the air intake casing and check the air intake between the recirculation and the outside air and viceversa by feeling by hand. If the result of the check is positive, do not replace the actuator. If there are further doubts as to the operation of the actuator, it is possible to carry out the check following the instructions described below if the air intake casing is easily accessible. See Test 5040DE CHECK ON OPERATION OF RECIRCULATION ACTUATORS | Move on to Step 7 | Incorrect operation of recirculation actuator. | Replace the recirculation actuator Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R |
| RECIRCULATION ACTUATOR FLAP CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | |
| 7 | Visually inspect that the air recirculation actuator flap completes its travel without any hinderance | End of diagnosis | 1. Flap travel incomplete. | 1.Free from air recirculation actuator flap from the impediment. |
| 2. Flap damaged. | 2.Replace the flap. | |||
| 3. Kinematic mechanism damaged. | 3.Repair kinematic mechanism. |