01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation not working

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Climate control › Climate control recirculation not working
Fault diagnosisClimate control recirculation not working

CLIMATE CONTROL RECIRCULATION NOT WORKING

AUTOMATIC AIR CONDITIONING

When the key on the switch panel is pressed, the recirculation function does not operate. The automatic climate control system comes only in the dual zone version.

1CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODEALL OKPROBLEMS ENCOUNTEREDACTION

When the vehicle engine is running, set the climate control system ECU to AUTO, operate the temperature knob to 22°C, set the fan speed to 8 bars and then press the recirculation key (check that the recirculation symbol appears on the display). Then feel the changes in air flow during flap open/closure. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake.

"When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up".

Move on to Step 21. The recirculation symbol does not appear on the display.1. Move on to Step 3
2. The recirculation symbol appears on the display (but the recirculation does not operate)2. Move on to Step 2
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment and check:

  • that there are no errors in the air recirculation actuator.
Move on to Step 6Errors in the recirculation actuator.Move on to Step 3
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,

  • the correct operation of the air recirculation actuator
  • correct activation of all the graphic LCD symbols on the display
Move on to Step 61. Air recirculation actuator not working1.Move on to Step 4
2. the recirculation symbol does not come on

2.Replace the climate control system control unit

Op. 5040D18 AIR CONDITIONING CONTROL UNIT - R.R.

4CHECK ELECTRICAL CONNECTIONSALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

Remove the control unit from the panel mount, disconnect the wiring connector from the control unit and check visually for any damage to the connector and reconnect correctly to check for false contacts.

Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator.

Move on to Step 5Electrical wiring connections loose or damaged.Renew the correct electrical connections
5RECIRCULATION MOTOR OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Then proceed as follows: with the engine running, manually engage the recirculation air intake function with the fan at the maximum speed. If the actuator works and the flap is driven, feel that the type of air flow alters during the movement. Deactivate the function by returning the actuator to the original condition. Identify the air intake casing grille on the vehicle and check by feeling the air intake with your hand in the switch from recirculation to outside air and vice versa. If the result of the check is positive, do not replace the actuator. To check further in case of doubts on the operation of the actuator, it is possible to carry out the check using the procedure described in the test if the air intake casing is easily accessible,

See Test 5040DE CHECK ON OPERATION OF RECIRCULATION ACTUATORS

Move on to Step 6Incorrect operation of recirculation actuator.

Replace the recirculation actuator

Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R

6RECIRCULATION ACTUATOR FLAP CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Visually inspect that the air recirculation actuator flap completes its travel without any hinderance.End of diagnosis1. Flap travel incomplete.1. Free the air recirculation actuator flap from the impediment.
2. Flap damaged.2. Replace the flap.
3. Kinematic mechanism/gears damaged.3. Repair kinematic mechanism.