Airbag failure warning light on
- Make
- Fiat
- Model
- Idea Factory Service Manual
- Year
- 2003–2012
- Section
- Instrument panel › Airbag failure warning light on
AIRBAG FAILURE WARNING LIGHT ON
The brake fluid warning light remains on with the handbrake not applied.
The (negative) brake fluid level signal is sent by the special sensor to the Body Computer Node which makes it available via the B-CAN network to the Instrument Panel Node.
The Instrument Panel Node lights up the dedicated warning light and displays the insufficient brake fluid level message; if the warning light is faulty the relevant message is displayed.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the EXAMINER diagnostic equipment and check the CAN NETWORK INFORMATION:
| Continue to Step 5 | Presence of faults in the CAN network | Continue as instructed by the tester | |
| Impossible to converse with the Body Computer | Continue to Step 2 | |||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Continue to Step 4 | The parameter is not plausible | Replace the Body Computer Op. 5505A32 | |
| Impossible to connect with the Body Computer control unit | Continue to Step 2 | |||
| 2 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Body Computer Node electrical power supply is correct. | Continue to Step 3 | Positive and/or earth electrical power supply fault. | Replace the defective component (if a fuse is involved, search for the cause of the problem). | |
| 3 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Body Computer Node. | Continue to Step 1 | Impossible to connect with the Body Computer control unit | Replace the Body Computer Op. 5505A32 | |
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Continue to Step 5 | |
| 5 | BRAKE FLUID LEVEL CHECK | All OK | Problems met | Operation |
| Check that the brake fluid level is not low | Continue to Step 9 | Brake fluid level too low | Continue to Step 6 | |
| 6 | TOP UP BRAKE FLUID LEVEL | All OK | Problems met | Operation |
| Restore the brake fluid level and check that the warning light goes out | End of diagnosis | The warning light does not go off | Continue to Step 7 | |
| 7 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Keeping the diagnostic equipment connected, check that there are no CAN errors at the BRAKE NODE | Continue to Step 8 | Presence of C-CAN faults | Continue to Step 14 | |
| 8 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation |
| Disconnect the connector from the fluid level sensor and, using a multimeter, check the efficiency of the connection to earth See E4010 INSTRUMENT PANEL | Continue to Step 9 | Faulty earth | Restore earth connection efficiency See E4010 INSTRUMENT PANEL | |
| 9 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation |
| Check the continuity of the cable from the connector to the Body computer See E4010 INSTRUMENT PANEL | Continue to Step 10 | Cable broken | Restore connection See E4010 INSTRUMENT PANEL | |
| 10 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect the Examiner and check the plausibility, at the Body Computer Node, of the handbrake applied parameter | Continue to Step 11 | The parameter is not plausible | Continue according to the instructions See table K72 HANDBRAKE APPLIED WARNING LIGHT | |
| 11 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect the Examiner or keep it connected and check the operation of the brake fluid level warning light at the Instrument Panel Node through active diagnosis | Continue to Step 12 | The warning light does not flash | Replace instrument panel Op. 5560B11 | |
| 12 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Instrument Panel Node electrical power supply is correct. | Continue to Step 13 | Positive and/or earth electrical power supply fault. | Replace the defective component (if a fuse is involved, search for the cause of the problem). | |
| 13 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. | Continue to Step 14 | Electrical connections not working. | Restore damaged electrical connection. | |
| 14 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Continue to Step 15 | The parameter is not plausible | Replace the Body Computer Op. 5505A32 | |
| 15 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the brake fluid reservoir and sensor Op. 3330C30 | |
The Air Bag failure warning light is lit up by a command sent via the C-CAN from the Air Bag Node to the Body Computer. The latter, sends the signal to the Instrument Panel Node via the B-CAN
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the EXAMINER diagnostic equipment and check the CAN NETWORK INFORMATION:
| Continue to Step 1 | Presence of faults in the CAN | Continue as instructed by the tester | |
| Impossible to converse with the Body Computer | Continue to Step 7 | |||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Keeping the diagnostic equipment connected, check for the following at the AIR BAG NODE:
| Continue to Step 2 | System/component fault | Continue according to the instructions for the diagnostic equipment | |
| Presence of C-CAN faults | Continue to Step 9 | |||
| 2 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. | Continue to Step 3 | There are errors | Continue in accordance with the instructions for the diagnostic equipment | |
| 3 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Instrument Panel Node electrical power supply is correct. | Continue to Step 4 | Positive and/or earth electrical power supply fault. | Replace the defective component (if a fuse is involved, search for the cause of the problem). | |
| 4 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. | Continue to Step 5 | Electrical connections not working. | Restore damaged electrical connection. | |
| 5 | CHECK WITH ACTIVE DIAGNOSIS | All OK | Problems met | Operation |
| With the Examiner in the Instrument Panel Node ambient, check, in active diagnosis, that the Air Bag warning light is correctly activated | Continue to Step 6 | The Air Bag warning light is not working properly | Replace the instrument panel Op. 5560B11 | |
| 6 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check, in the Body Computer Node ambient, that there are no errors and that the warning light status varies | Continue to Step 9 | Impossible to connect with the Body Computer control unit. | Continue to Step 7 | |
| Errors present. | The parameter values do not change | |||
| The parameter values do not change | Continue to Step 9 | |||
| 7 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Body Computer Node electrical power supply is correct. | Continue to Step 8 | Positive and/or earth electrical power supply fault. | Replace the defective component (if a fuse is involved, search for the cause of the problem). | |
| 8 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Body Computer Node. | Continue to Step 6 | Impossible to connect with the Body Computer control unit. | Replace the Body Computer Op. 5505A32 | |
| 9 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Replace the Body Computer Op. 5505A32 | |
Parts & tools for this job For 2003 Fiat Idea
- TOOLOBD2 scanner with SRSSearch: OBD2 scanner ABS SRS
- TOOLTrim removal tool kitSearch: trim removal tool kit
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.