RECHARGING WARNING LIGHT ON CONSTANTLY
After the engine has started, the generator warning light on the Instrument Panel Node always stays on.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the D+ terminal on the alternator delivers a voltage of at least 12 V | Continue to Step 1 | The alternator does not deliver 12 V | Continue to Step 9 | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors | Continue to Step 5 | Impossible to connect with the Instrument Panel control unit | Continue to Step 2 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| 2 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Instrument Panel Node electrical power supply is correct | Continue to Step 3 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 3 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected | Continue to Step 4 | Electrical connections not working | Restore damaged electrical connections | |
| 4 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Instrument Panel Node | Continue to Step 6 | Impossible to connect with the Instrument Panel | Replace the instrument panel Op. 5560B11 | |
| 5 | CHECK WITH ACTIVE DIAGNOSIS | All OK | Problems met | Operation |
| With the Examiner in the Instrument Panel Node ambient, check, in active diagnosis, that the generator warning lights are correctly activated | Continue to Step 6 | The alternator warning light does not come on | Replace the instrument panel Op. 5560B11 | |
| 6 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner check, in the Body Computer Node ambient, that there are no errors | Continue to Step 1 | Impossible to connect with the Body Computer control unit | Continue to Step 7 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| 7 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Body Computer Node electrical power supply is correct | Continue to Step 8 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 8 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Body Computer Node | Continue to Step 6 | Impossible to connect with the Body Computer control unit | Replace the Body Computer Node Op. 5505A32 | |
| 9 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check the continuity and insulation of the electrical circuit between the battery, starter motor and alternator See E5010 STARTING AND RECHARING | Continue to Step 10 | Connections faulty | Restore the correct connections, if necessary replace the faulty components See E5010 STARTING AND RECHARING | |
| 10 | CHECKING BATTERY CHARGE | All OK | Problems met | Operation |
| Check the battery charge | Continue to Step 11 | Battery discharged | Recharge the battery Op. 5530B14 | |
| Battery discharged and cannot be recharged | Replace the battery Op. 5530B10 | |||
| 11 | CHECKING ALTERNATOR | All OK | Problems met | Operation |
1.3 JTD 16v 1.9 JTD 8v | Check, carrying out the Test See Test 5530AB Alternator operation test, that the alternator is working properly | End of diagnosis | Alternator operating faults | Replace the alternator Op. 5530A10 |
1.3 JTD 16v 1.9 JTD 8v | Check, carrying out the Test See Test 5530AB Alternator operation test, that the alternator is working properly | End of diagnosis | Alternator operating faults | Replace the alternator Op. 5530A14 |
‹ Prev Mode button not workingNext › One warning light activated by steering column switch unit not working
Parts & tools for this job For 2003 Fiat Idea
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Fiat Idea
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.