01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Idea Factory Service Manual (2003-2012)22 · Fault diagnosis
22 · Diagnostics

Recharging warning light on constantly

Make
Fiat
Model
Idea Factory Service Manual
Year
2003–2012
Section
Instrument panel › Recharging warning light on constantly
Fault diagnosisRecharging warning light on constantly

RECHARGING WARNING LIGHT ON CONSTANTLY

After the engine has started, the generator warning light on the Instrument Panel Node always stays on.

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check that the D+ terminal on the alternator delivers a voltage of at least 12 VContinue to Step 1The alternator does not deliver 12 VContinue to Step 9
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errorsContinue to Step 5Impossible to connect with the Instrument Panel control unitContinue to Step 2
There are errorsContinue in accordance with the instructions for the diagnostic equipment
2ELECTRIC POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correctContinue to Step 3Positive and/or earth electrical power supply faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
3CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connectedContinue to Step 4Electrical connections not workingRestore damaged electrical connections
4CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Instrument Panel NodeContinue to Step 6Impossible to connect with the Instrument PanelReplace the instrument panel Op. 5560B11
5CHECK WITH ACTIVE DIAGNOSISAll OKProblems metOperation
With the Examiner in the Instrument Panel Node ambient, check, in active diagnosis, that the generator warning lights are correctly activatedContinue to Step 6The alternator warning light does not come onReplace the instrument panel Op. 5560B11
6CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Body Computer Node ambient, that there are no errorsContinue to Step 1Impossible to connect with the Body Computer control unitContinue to Step 7
There are errorsContinue in accordance with the instructions for the diagnostic equipment
7ELECTRICAL POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Body Computer Node electrical power supply is correctContinue to Step 8Positive and/or earth electrical power supply faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
8CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Body Computer NodeContinue to Step 6Impossible to connect with the Body Computer control unitReplace the Body Computer Node Op. 5505A32
9ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the continuity and insulation of the electrical circuit between the battery, starter motor and alternator See E5010 STARTING AND RECHARINGContinue to Step 10Connections faultyRestore the correct connections, if necessary replace the faulty components See E5010 STARTING AND RECHARING
10CHECKING BATTERY CHARGEAll OKProblems metOperation
Check the battery chargeContinue to Step 11Battery dischargedRecharge the battery Op. 5530B14
Battery discharged and cannot be rechargedReplace the battery Op. 5530B10
11CHECKING ALTERNATORAll OKProblems metOperation

1.3 JTD 16v

1.9 JTD 8v

Check, carrying out the Test See Test 5530AB Alternator operation test, that the alternator is working properlyEnd of diagnosisAlternator operating faultsReplace the alternator Op. 5530A10

1.3 JTD 16v

1.9 JTD 8v

Check, carrying out the Test See Test 5530AB Alternator operation test, that the alternator is working properlyEnd of diagnosisAlternator operating faultsReplace the alternator Op. 5530A14