landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

WATER PUMP > < VISCOUS COUPLING, FAN BLADES, PULLEY AND FAN COWL
Page 222
background image

26

COOLING SYSTEM

RANGE ROVER

2

REPAIR

Refit

6. Reverse removal procedure. Ensuring fan

blades are fitted correctly. Fan is marked
FRONT and should be fitted with word FRONT
closest to radiator. Tighten to

35 Nm.

THERMOSTAT

Service repair no - 26.45.01

Remove

1. Partially drain cooling system, until coolant level

is below thermostat housing.

2. Disconnect hose from thermostat housing.
3. Disconnect electrical connections to water

temperature switch.

4. Remove outlet elbow.
5. Withdraw thermostat.

WATER PUMP > < VISCOUS COUPLING, FAN BLADES, PULLEY AND FAN COWL