Checking flame monitor G64
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Checking flame monitor G64
Aux. heater/heater boosterChecking flame monitor G64
Checking flame monitor G64
Remove heater unit -B4W- or -D4W-.
Remove heater control unit J162.
Pull connector housing off control unit.
Measure resistance between chamber 13 and chamber 14 at brown and blue cable:

R = resistance in Ω
t = temperature in o C
Please measure resistance at prevailing temperature.
Evaluation:
- Defective > 3040 Ω = open circuit
- Defective < 780 Ω = short circuit
Parts & tools for this job For 1996 SEAT Alhambra
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Alhambra 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.