Regulation of auxiliary heater -D3W-
The auxiliary heater -D3W- is intended to heat the coolant and thereby assist the heating output of the engine.
Various operating modes can be set depending on heat required in heating circuit:
After the engine is started at an ambient temperature of below 5 °C and if the coolant temperature is below 75 °C, the heater unit switches on.
If the heat required is 3000 watts (100% of heating output), then the heater unit operates in full load mode. The coolant temperature increases up to 85 °C (maximum).
If the coolant temperature reaches approx. 85 °C, then the heater unit operates in part load mode.
If the heat requirement is larger than 1500 watts (50% of heating output) then the coolant temperature will decrease. When the temperature reaches approx. 78 °C, the heater unit operates in full load mode again.
If, because of the low heat requirement, the coolant temperature increases further, at approx. 88 °C the heater unit goes into the run-on phase and is switched off after approx. 100 seconds.