Diagnosis with the <span class="tool">diagnostic tester 5019</span>
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Diagnosis with the <span class="tool">diagnostic tester 5019</span>
Diagnosis with the <span class="tool">diagnostic tester 5019</span>
- Diagnostic tester 5019

The heater control unit J162 in the -B4W-/ -D4W- and in the -D3W- receives data from the electrical and electronic components:
- Coolant temperature sender for heater G241
- Flame monitor G64
- Overheating sensor G189
This data is processed by the heater control unit J162 in the -B4W-/ -D4W- and -D3W-. The heater control unit J162 then controls the combustion air blower V6, the glow plug for heater Q9 and the metering pump V54. The heater control unit J162 is equipped with a fault memory and recognises the fault that is currently present during the heating period. The current fault can be read as a fault code using diagnostic tester 5019. Therefore, please connect the diagnostic tester 5019 immediately.
If fault code numbers are displayed, then the causes of the faults must be rectified according to the instructions in the fault table. The fault code numbers of the diagnostic tester must be cleared after the repair. After a road test, please use the diagnostic tester 5019 to read the heater control unit J162 in the -B4W-/ -D4W- or -D3W- again.
The meanings of the fault code numbers are described in the fault table Chapter “Diagnosis with the diagnostic tester 5019”.