Checking flame monitor G64
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Checking flame monitor G64
Aux. heater/heater boosterChecking flame monitor G64
Checking flame monitor G64
Remove heater unit Chapter “Removing and installing heater unit”.
Remove cover for combustion air blower V6 Item “Dismantling and assembling heater unit”.
Pull connector housing (2) off heater control unit J162 (3 ).

Measure resistance between chamber 2 and chamber 1 at brown cables.

R = resistance in Ω
t = temperature in °C
Please measure resistance at prevailing temperature.
Evaluation:
- Defective > 3040 Ω = open circuit
- Defective < 780 Ω = short circuit