Start procedure
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Start procedure
Start procedure
After each engine start the flame monitor G64 must inform the control unit within 130 seconds after the heating has switched on, that the flame is burning normally. If this not the case, then the heater unit automatically attempts a second start. If, after the second start, the flame still does not burn normally, the heater will remain switched off until the engine is started again.
In part load mode the combustion air blower V6 operates at reduced rpm and the metering pump V54 delivers only part of the fuel (reduced pulse frequency).
The start procedure is aborted if:
- flame monitor G64 registers that the flame is not burning normally within 130 seconds.
- The temperature or overheating sensor detects a temperature greater than 125 °C.
- temperature sensor G18 and the overheating sensor G189 exceeds 15 °C.
- vehicle diagnostic, testing and information system VAS 5051A
Parts & tools for this job For 1996 SEAT Alhambra
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Alhambra 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.