Checking flame monitor G64
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Checking flame monitor G64
Aux. heater/heater boosterChecking flame monitor G64
Checking flame monitor G64
Remove heater unit Chapter “Removing and installing heater unit”.
Remove heater control unit J162 Chapter “Removing heater control unit J162”.
Pull connector housing off control unit.
Measure resistance between chamber 2 and chamber 1 at brown and blue cable.

R = resistance in Ω
t = temperature in °C
Please measure resistance at prevailing temperature.
Evaluation:
- Defective > 3040 Ω = open circuit
- Defective < 780 Ω = short circuit
Parts & tools for this job For 1996 SEAT Alhambra
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Alhambra 1996 cabin filter
As an Amazon Associate we earn from qualifying purchases.