Test procedure
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Test procedure
Test procedure
Disconnect 8-pin connector (T8) from heater unit.
Set measuring range selector switch on hand multimeter V.A.G 1526B to DC voltage measurement, measuring range 20 V.
Connect hand multimeter V.A.G 1526B to chamber -T8/2- and chamber -T8/6- of disconnected 8-pin connector using cables from auxiliary measuring set V.A.G 1594C.

Switch on ignition and start engine.
Display on the hand multimeter V.A.G 1526B:
- At ambient temperatures below approx. 10 °C: approx. 12 V
Unclip ambient temperature switch (1) from bracket at front left in plenum chamber. Depending on vehicle equipment, the ambient temperature switch (1) may be located on the wiper motor wiring harness or behind the wiper motor.

Spray ambient temperature switch with cold spray, if necessary, and observe display on hand multimeter V.A.G 1526B.
If values do not change when ambient temperature switch F38 is sprayed, or if specified rated values are not achieved:
Check cables and/or connectors to ambient temperature switch F38 according to current flow diagram.
If cables and/or connectors to ambient temperature switch F38 are OK according to current flow diagram:
Please replace ambient temperature switch F38.
Note
- ambient temperature switch F38 switches on the auxiliary heater only if the engine is running and the coolant temperature is below approx. 77 °C. The ambient temperature must not exceed approx. 10 °C.