Start signals
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Start signals
Aux. heater/heater boosterStart signals
Start signals
- Terminal 30 from fuse box
- Terminal L from alternator; -engine running-
- temperature sensor G18 less than 75 °C
- ambient temperature switch F38 less than approx. 10 °C
Note
- flame monitor G64 is greater than 70 °C it will be cooled for 4 minutes at a higher blower speed. Then the unit will start.
Parts & tools for this job For 1996 SEAT Alhambra
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Alhambra 1996 cabin filter