Start procedure
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Start procedure
Start procedure
After each engine start the flame monitor G64 must inform the control unit within 130 seconds after the heating has switched on, that the flame is burning normally. If this not the case, then the heater unit automatically attempts a second start. If, after the second start, the flame still does not burn normally, the heater will remain switched off until the engine is started again.
In part load mode the combustion air blower V6 operates at reduced rpm and the metering pump V54 delivers only approx. 50% of fuel (reduced pulse frequency).
The start procedure is aborted if:
- The flame monitor registers that the flame is not burning normally within 130 seconds.
- The temperature or overheating sensor detects a temperature greater than approx. 125 °C.
- The temperature difference between the temperature and overheating sensors exceeds 15 °C.
- Chapter “Diagnosis with the diagnostic tester 5019”.