Fault table
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Supplementary heating › Fault table
Aux. heater/heater boosterFault table
Fault table
| Fault code number and meaning | Possible cause of fault | Fault rectification with remarks |
|---|---|---|
| 000 | ||
| No malfunction | ||
| 001 | ||
| Overvoltage warning (> 16 V) | Controller | Renew |
| 002 | ||
| Undervoltage warning (< 10.2 V) | 2nd. battery | Charge |
| 010 | ||
| Overvoltage shut-off (> 16 V) | 2nd. battery | Voltage was present for longer than 20 seconds |
| 011 | ||
| Undervoltage shut-off (< 10.2 V) | 2nd. battery | Voltages were present for longer than 20 seconds |
| 012 | ||
| Overheating | Temperature at flame monitor G64 or overheating sensor G189 too high (> 125 °C). | Air in coolant circuit, bleed Chapter “Bleeding coolant circuit” |
| 014 | ||
| Evaluation of temperature difference between flame monitor G64 and overheating sensor G189 | Air in coolant circuit, flame monitor G64 defective, overheating sensor G189 defective | Bleed Chapter “Bleeding coolant circuit”, check flame monitor G64 Chapter “Checking flame monitor G64”, check overheating sensor G189 Chapter “Checking overheating sensor G189” |
| 015 | ||
| Continuous shut-down | Air in coolant circuit, | Bleed Chapter “Bleeding coolant circuit” Clear fault memory Chapter “Diagnosis with the diagnostic tester 5019” |
| 017 | ||
| Overheating | Temperature too high (> 130 °C) at overheating sensor G189 and coolant temperature sender for heater G241 | Air in coolant circuit, bleed Chapter “Bleeding coolant circuit” Check overheating sensor G189 Chapter “Checking overheating sensor G189” Check coolant temperature sender for heater G241 Chapter “Checking coolant temperature sender for heater G241” Clear fault memory Chapter “Diagnosis with the diagnostic tester 5019” |
| 020 | ||
| Glow plug for heater Q9 | Defective | Renew |
| 021 | ||
| Short circuit on the glow plug for heater Q9 | Short circuit on the connection or in the glow plug | Renew if necessary. |
| 030 | ||
| Combustion air blower V6 | Blocked | Renew |
| 032 | ||
| Combustion air blower V6 | Open circuit | Check the connection, replace if necessary |
| 038 | ||
| Fresh air blower V2 | Open circuit | Check, |
| 039 | Renew if necessary. | |
| Fresh air blower V2 | Short circuit | |
| 041 | ||
| Circulation pump V55 | Open circuit | Check, replace if necessary |
| 042 | and bleed coolant circuit Chapter “Bleeding coolant circuit” | |
| Circulation pump V55 | Short circuit | |
| 047 | ||
| Metering pump V54 | Short circuit | Check, |
| 048 | Renew if necessary. | |
| Metering pump V54 | Open circuit | |
| 050 | ||
| Continuous shut-down | Unsuccessful start attempts | Erase fault memory Chapter “Diagnosis with the diagnostic tester 5019”. |
| 051 | ||
| Time overrun | When blowing flame monitor G64 cold with combustion air blower V6 | Check flame monitor G64 Chapter “Checking flame monitor G64”. |
| 052 | ||
| Time overrun | Safety time exceeded after several start attempts | Check: exhaust pipe fuel volume, combustion air induction |
| 053 | ||
| Flame failure from the high control level | Metering pump V54 (quantity delivered) Exhaust pipe (blocked) Combustion air (insufficient) | Check, |
| 054 | Flame monitor G64 (values) | Replace if necessary Chapter “Fuel supply to auxiliary heaters -B4W- / -D4W-” |
| Flame failure from medium control level | The fault memory is cleared if the start is successful. | |
| 056 | Heater is permanently switched off. | |
| Flame failure from low control level | Clear fault memory after checking and replacing. | Switch on heater once again. |
| 060 | ||
| Coolant temperature sender for heater G241 | Open circuit | Check water temperature, |
| 061 | Check coolant temperature sender for heater G241, | |
| Coolant temperature sender for heater G241 | Short circuit | Replace if necessary Chapter “Removing coolant temperature sender for heater G241” |
| 064 | ||
| Flame monitor G64 | Open circuit | Flame monitor G64 |
| 065 | Checking Chapter “Checking flame monitor G64” | |
| Flame monitor G64 | Short circuit | |
| 071 | ||
| Overheating sensor G189 | Open circuit | Check, |
| 072 | ||
| Overheating sensor G189 | Short circuit | Replace if necessary Chapter “Removing overheating sensor G189” |
| 090 | ||
| Heater control unit J162 | Error in microprocessor, (memory present) | Replace if necessary Chapter “Removing heater control unit J162” |
| 091 | ||
| Interference voltage | In vehicle electrical system or other voltage sources | Rectify |
| 092 to 103 | ||
| Heater control unit J162 | Defective | Replacing Chapter “Removing heater control unit J162”. |