Check cooling power of the air conditioning
- Make
- SEAT
- Model
- Exeo
- Year
- 2008–2013
- Section
- Heating, air conditioning › Check cooling power of the air conditioning
Check cooling power of the air conditioning
- Vehicle diagnostic, testing and information system VAS 505x

- Normal thermometer (to measure temperature or a thermometer with two sensors to measure left and right tempearutres at the same time)
- Digital thermometer SAT 4002 replaced by the digital thermometer SAT 4013

- Leak detector A.A.SAT 4007B

- The ambient temperature is more than 15° C.
- Radiator and condenser clean (clean if necessary)
- The poly V-belt of the compressor has a good condition and is tensioned correctly and that the belt pulley drives the compressor.
- All air ducts, covers and seals OK and properly fitted
- Air flow through dust and pollen filter not impeded by dirt
- Vehicle not exposed to direct sunlight.
- The engine is at operating temperature.
- Fault memory interrogated , all displayed faults eliminated and fault memory erased
- The encoding has been checked and corrected where necessary; read the measured value block.
- Perform the basic configuration.
- All dash panel air vents are open.
- Bonnet closed
- Climatronic control unit J255:
Operation mode “Auto”
“LO” temperature setting (for driver's and passenger's side)
Compressor on (the lamp in Econ button is not lit)
- Functions with engine running (and air conditioner switched on):
The radiator fan(s) V7 run(s) or is/are activated as soon as a certain pressure is exceeded in the refrigerant circuit (the speed depends on the pressure in the refrigerant circuit and the engine temperature).
Note
- Climatronic control unit J255 in air conditioner operation of the refrigerant fan is immediately activated when switching on the compressor, or the refrigerant fan is first actuated when a pressure of approx. 9 bar is exceeded in the refrigerant circuit. 9 bar
Fresh air blower V2 running at maximum speed
The air conditioner switches to recirculated-air mode (approx. 1 minute after starting vehicle, fresh-air/air flow flaps… are closed and recirculated-air flap opened, air is drawn in by fresh air blower V2 from passenger's footwell).
Note
- If one of these test requirements is not fulfilled, interrogate fault memory and perform final control diagnosis.
Measure ambient temperature (it must be over 15 °C).
Close doors, bonnet, windows and sunroof.
Open all dash panel vents.
Switch on ignition.
Select the “Econ” mode on the operating and display unit, Climatronic control unit J255 (lamp in Econ button lights up).
Start the engine.
Start air conditioner self-diagnosis.
Select display group “001” in “Reading measured value block” function.
Check display in display zones:
Display zone “2” shows 0% (compressor off).
Display zone “4” indicates that the pressure in the refrigerant circuit at the measured ambient temperature is equal to or greater than the value in the table.
| Ambient temperature in °C | Pressure display (in bar absolute) |
|---|---|
| 15 | 4,7 |
| 20 | 5,6 |
| 25 | 6,6 |
| 30 | 7,6 |
| 35 | 8,8 |
Note
- corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to roughly absolute. On the scales of most pressure gauges, corresponds to an absolute pressure of one bar (can be seen from mark below ).
- The pressure in the refrigerant circuit depends on the ambient temperature. Due to heat radiation from components (for example the coolant radiator), for a warm engine at normal running temperature, the indicated pressure is a above the corresponding atmospheric temperature.
- high-pressure sender G65 and . If no fault is found at the high-pressure sender, there is not enough refrigerant in the circuit and the vehicle must be taken to a specialist air conditioner workshop.
If pressure in refrigerant circuit is OK.
Switch on compressor by selecting “Auto” mode on operating and display unit, Climatronic control unit J255 (lamp in Econ button does not light up).
Set “Lo” temperature (for driver's and passenger's side) on operating and display unit, Climatronic control unit J255.
Set air outflow direction on operating and display unit, Climatronic control unit J255 to “dash panel vents”.
Select display group “001” in “Reading measured value block” function.
Check display in display zones:
Display zone “2” shows a signal ratio of greater than 30% (the air conditioner compressor regulating valve N280 is actuated, the compressor is switched on).
Display zone “1” shows a current greater than 0.3 A (the current is flowing via the air conditioner compressor regulating valve N280, the compressor is switched on).
The pressure displayed in zone “4” rises above the value when the compressor is switched off.
Note
- air conditioning system, compressor regulating valve N280 is activated in such a way by the operating and display unit, Climatronic control unit J255, that the air temperature downstream of the evaporator reaches the specified value (approx. 2 to 5 °C). After starting the vehicle, a value greater than 75% (0.55 A) is displayed depending on the measured temperature, engine speed and electrical system voltage. As soon as the temperature measured by the evaporator output temperature sender G263 approaches the specified value, the actuation is reduced and the compressor output is reduced.
- Under certain operating conditions, residual moisture in refrigerant circuit may cause ice to form at compressor regulating valve. Due to the formation of this ice, the regulation of the compressor is inhibited, the evaporator is cooled too much and will freeze. Freezing of the evaporator can lead to the following complaints:
- - Repeated or sporadic failure of air conditioner (no cooling/heat output) after a long journey; air conditioner functions properly again after a short delay following engine shutoff.
- button; air conditioner functions properly again after a short delay following engine shutoff.
- Precautions:
- evaporator outlet temperature sender G263.
- evaporator output temperature sender G263 (incorrect measured value can cause evaporator to ice up).
- air conditioning system compressor regulating valve N280 is not currently being actuated, the vehicle is to be taken to a specialist air conditioner workshop.
- - Check refrigerant pipe between evaporator and reservoir (thick pipe, low-pressure end) with engine running. If this pipe is severely iced up when problem occurs (thin layer of ice is permissible), this also indicates that evaporator temperature is too low.
- - Make the specialist air conditioner workshop aware of any problem encountered. The necessary work can only be performed by such specialists (discharging of refrigerant circuit, replacement of reservoir and subsequent evacuation of refrigerant circuit for at least 3 hours).
- shows no or insufficient current, check actuation of air conditioning system compressor regulating valve N280
- does not vary and the compressor controlling is correct (display field and ), this indicates a fault in the refrigerant circuit. Visit a specialist air conditioner workshop.
Press recirculated-air flap button (“recirculated-air mode” symbol in button lights).
Set engine speed to 2000 rpm (start of time measurement).
Select display group “010” in “Reading measured value block” function.
Compare measured value indicated in display zone “1” (for evaporator outflow temperature sender G263) to values in graph.

Depending on the ambient temperature, the measured ambient temperature must be within the stated tolerance range after 5 minutes.
Note
- evaporator outflow temperature sender G263. Compare measured values shown in display groups , zone and , zones and :
- or only differs slightly from the measured value in display group , Perform "Measures to be taken if readout does not match specification" Chapter “Fault Finding if readout does not match specification”
- evaporator outlet temperature sender G263 is greater than the measurement value of the outlet temperature sender, left side G150 and outlet temperature sender, right side G151, check the evaporator outlet temperature sender G263 that it is installed correctly and carry out the electric test for this sensor .
- (thick pipe).
If the measured value of the evaporator outflow temperature sender G263 (and thus the air conditioner cooling output) is OK:
Compare measured value indicated in zone “1” of display group “010” (for evaporator outflow temperature sender G263) to measured values of display group “009”, zones “3” and “4” (left vent temperature sender G150 and right vent temperature sender G151).
After 5 minutes, the measured values in display group “009”, zones “1” and “4” (left vent temperature sender G150 and right vent temperature sender G151) must not be more than 3 °C higher than the value in zone “1” of display group “010” (for evaporator outflow temperature sender G263).
Note
- , display zones and :
- or , check the actuator motor of the temperature flap where the measurement value is not OK (left temperature flap control motor V158 or right temperature flap control motor V159), and carry out the electric test for the sensor left outlet temperature sender G150 and right outlet temperature sender G151 by .
- or of display group is lower than that in display zones of display group . check evaporator outflow temperature sender G263, left vent temperature sender G150 and right vent temperature sender G151 for proper installation and contact resistance at electrical connections and replace defective sender if necessary.
- left vent temperature sender G150 or the right vent temperature sender G151 and at the left temperature flap control motor V158 or the right temperature flap control motor V159, perform measures to be taken in the event of temperature increase downstream of evaporator Chapter “Fault Finding if temperature increases downstream of evaporator”.
- dash panel vents, can additionally be measured with the handheld multimeter VAG 1526E with the temperature sensor VAG 1526B/1.
- , display zones and indicates the measured value for the left footwell vent temperature sender G261 and the right footwell vent temperature sender G262. As the air flow in mode is only routed to the dash panel vents, these two senders indicate an imprecise value in this setting. Pressing the button makes it possible to incorporate these senders into the test as well.