01 Technical data02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Automatic gearbox, control, assembly, housing18 Automatic gearbox, gears, control19 Final drive, differential, differential lock20 Front suspension, drive shafts21 Rear suspension, drive shaft22 Wheels, tyres. axle align23 ABS, ADR, TCS, EDL, ESP24 Brake, brake mechanics25 Brakes, hydraulics, regulator, servo26 Steering27 Body front28 Body centre, roof, frame29 Body, rear30 Bonnet, flaps, cab, central locking31 Front door, central locking32 Rear door, sliding door, wing doors, central locking33 Sliding roof34 Bumper35 Glazing/window mechanism36 Exterior equipment37 Interior equipment38 Passenger protection39 Trim, noise insulation40 Seat frames41 Seat padding, covers42 Air conditioner43 Infotainment44 Windscreen wipe/wash system45 Lights, lamps, switches outside46 Lights, lamps, switches inside, anti-theft system47 Wiring
SEAT Exeo (2008-2013)42 · Air conditioner
42 · Heating & A/C

Fitting

Make
SEAT
Model
Exeo
Year
2008–2013
Section
Heating, air conditioning › Fitting
Air conditionerFitting

Fitting

Heating, ventilation, air conditioning system · Heating, air conditioning · Components for control and regulation of air conditioner · Exeo · Edition 08.2009

In area of hole (E) check gap between noise insulation mat and floor panel (noise insulation mat must not make contact with installed condensate drain valve (C)).

Check condensate drain valve (C); it must not be gummed up with wax or underseal.

Check for contamination of condensate drain hose (B) and clean hose before fitting.

Fully insert condensate drain valve (C) as shown (use soap solution as lubricant if applicable).

A87-0431

Check condensate drain hose (B). It must not be twisted or crushed and must be positioned in recess provided in floor covering.

Fasten the clip (A).

Re-install all components removed in reverse order.