Workshop Manuals Factory service & repair SEAT
01 Technical data02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Automatic gearbox, control, assembly, housing18 Automatic gearbox, gears, control19 Final drive, differential, differential lock20 Front suspension, drive shafts21 Rear suspension, drive shaft22 Wheels, tyres. axle align23 ABS, ADR, TCS, EDL, ESP24 Brake, brake mechanics25 Brakes, hydraulics, regulator, servo26 Steering27 Body front28 Body centre, roof, frame29 Body, rear30 Bonnet, flaps, cab, central locking31 Front door, central locking32 Rear door, sliding door, wing doors, central locking33 Sliding roof34 Bumper35 Glazing/window mechanism36 Exterior equipment37 Interior equipment38 Passenger protection39 Trim, noise insulation40 Seat frames41 Seat padding, covers42 Air conditioner43 Infotainment44 Windscreen wipe/wash system45 Lights, lamps, switches outside46 Lights, lamps, switches inside, anti-theft system47 Wiring
SEAT Exeo (2008-2013)42 · Air conditioner
42 · Heating & A/C

Safety measures when handling refrigerant

Make
SEAT
Model
Exeo
Year
2008–2013
Section
Heating, air conditioning › Safety measures when handling refrigerant
Air conditionerSafety measures when handling refrigerant

Safety measures when handling refrigerant

Heating, ventilation, air conditioning system · Heating, air conditioning · Instructions for repair work on vehicles with air conditioning and how to work with the refrigerant · Exeo · Edition 07.2012

The following safety measures are to be observed in Germany for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened Chapter “Safety precautions”. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant escape although all safety measures are observed, do not inhale the mixture of refrigerant and air which then forms.

Therefore, switch on extraction systems and wear rubber gloves and protect eyes with safety goggles.

Reason

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning

It is recommended that you always have an eye-bath ready for use in case it is needed.

Should liquid refrigerant get into the eyes, thoroughly rinse the eyes with water for about 15 minutes.

Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.

Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body even though all safety measures have been observed, these components must also be thoroughly rinsed with cold water immediately for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.

Parts & tools for this job For 2008 SEAT Exeo

As an Amazon Associate we earn from qualifying purchases.