Refrigeration agent circuit: repairs
- Make
- SEAT
- Model
- Exeo
- Year
- 2008–2013
- Section
- Heating, air conditioning › Refrigeration agent circuit: repairs
‹ Prev Fault Finding if temperature increases downstream of evaporatorNext › Refrigeration agent circuit: repairs
Air conditionerRefrigeration agent circuit: repairs
Refrigeration agent circuit: repairs
Note
- Air conditioner with refrigerant R134a.
- The compressor is always driven when engine is running; there is no magnetic clutch. Engine is therefore not to be started unless refrigerant circuit has been properly assembled. If, for example, refrigerant pipes have not been connected to compressor, heat generation inside compressor with engine running may lead to destruction of compressor. The internal heat generation is caused by the compressor operating against a fixed resistance even at approximately 0% delivery rate (closed circuit).
- To stop the compressor being destroyed when the refrigerant circuit is empty, it is designed such that delivery is reduced to roughly 0 % and lubrication is maintained by way of an internal oil circuit with the oil left in the compressor.
- Air conditioning - with refrigerant R134a
- , and compressors Air conditioner with refrigerant R134a and Spare parts catalogue.
- The stated diameters for the O-ring seals and the tightening torque also apply to refrigerant pipe/hose unions between the individual components.
- Air conditioner with refrigerant R134a
- Chapter “Refrigeration performance of the air conditioning: testing”
- Air conditioner - with refrigerant R134a
- Air conditioning with refrigerant R134a
‹ Prev Fault Finding if temperature increases downstream of evaporatorNext › Refrigeration agent circuit: repairs
Parts & tools for this job For 2008 SEAT Exeo
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit
As an Amazon Associate we earn from qualifying purchases.