01 Technical data02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Automatic gearbox, control, assembly, housing18 Automatic gearbox, gears, control19 Final drive, differential, differential lock20 Front suspension, drive shafts21 Rear suspension, drive shaft22 Wheels, tyres. axle align23 ABS, ADR, TCS, EDL, ESP24 Brake, brake mechanics25 Brakes, hydraulics, regulator, servo26 Steering27 Body front28 Body centre, roof, frame29 Body, rear30 Bonnet, flaps, cab, central locking31 Front door, central locking32 Rear door, sliding door, wing doors, central locking33 Sliding roof34 Bumper35 Glazing/window mechanism36 Exterior equipment37 Interior equipment38 Passenger protection39 Trim, noise insulation40 Seat frames41 Seat padding, covers42 Air conditioner43 Infotainment44 Windscreen wipe/wash system45 Lights, lamps, switches outside46 Lights, lamps, switches inside, anti-theft system47 Wiring
SEAT Exeo (2008-2013)42 · Air conditioner
42 · Heating & A/C

Safety precautions

Make
SEAT
Model
Exeo
Year
2008–2013
Section
Heating, air conditioning › Safety precautions
Air conditionerSafety precautions

Safety precautions

Heating, ventilation, air conditioning system · Heating, air conditioning · Safety measures for working on vehicles with air conditioning and for handling refrigerant · Exeo · Edition 08.2009

The following safety measures are to be observed in Germany for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit is to be discharged first should repair work require the refrigerant circuit to be opened (Chapter “Safety precautions”). Any contact with the refrigerant liquid or vapours of this liquid must be avoided. Should refrigerant nevertheless escape, avoid inhaling the resultant refrigerant/air mixture.

In this situation, turn on any suction system and protect hands with gloves and the eyes with protective glasses.

Reason:

The intensive action of the refrigerant on unprotected parts of the body may lead to freezing of those parts.

Warning

Always keep an eye wash flask close to hand.

Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.

Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.

The medical assistance must be given all of the details of the refrigerant causing the problem.

Should refrigerant come into contact with other parts of the body despite compliance with all the pertinent safety measures, these are similarly to be rinsed thoroughly with cold water without delay for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reason:

If the refrigerant comes into contact with flame or hot elements, the gas in the refrigerant is chemically separated. Inhalation of the resultant toxic decomposition products leads to dry coughing and nausea.