Removing and installing reservoir
- Make
- SEAT
- Model
- Exeo
- Year
- 2008–2013
- Section
- Heating, air conditioning › Removing and installing reservoir
Removing and installing reservoir
- Venting device for the air conditioner SAT 4006D

- Torque wrench kit SAT 8010

Discharge refrigerant circuit Air conditioner with refrigerant R134a.
Remove entire front bumper General body repairs, exterior Rep. gr. 63.
Move the lock carrier to service position (not always necessary, depends on vehicle) General body repairs, exterior Rep. gr. 50.
If applicable, remove charge air cooler/secondary air pump motor (not always necessary, depends on vehicle) Engine, mechanics Rep. gr. 21 and Engine, mechanics Rep. gr. 26
Unscrew bolts (A) and detach refrigerant pipes (B) and (C).

Unscrew bolts (A).

Detach lug at holder for reservoir (B) from body.
Remove the reservoir and bracket.
Slacken off bolt (C) and pull reservoir out of holder (D).
Note
- Seal open pipe connections.
- Parts List.
- Keep the reservoir closed for as long as possible, only remove the caps immediately before installation (the reservoir contains a desiccant bag which soon becomes saturated with moisture and hence unusable when the reservoir is open)
Attach in reverse order; note the following:
Before fitting reservoir Air conditioner with refrigerant R134a
Check type of seal at connections and refrigerant pipes (must be designed for same type of seal) Chapter “Refrigerant pipe connections at components (different versions)” and Parts List
Note
- (from evaporator) and (to compressor).
- Air conditioner with refrigerant R134a.
- Air conditioner with refrigerant R134a
- Air conditioner with refrigerant R134a
Insert reservoir in holder (D).

Engage holder (D) with lug (B).
Insert and tighten bolts (A) (tightening torque 8 Nm).
Replace O-rings (D); for version refer to Spare parts catalogue

Turn the reservoir such that the two refrigerant pipes (B) and (C) can be inserted without strain in the reservoir. In doing so, pay attention to correct assignment of connections.
Use bolt (A) to attach refrigerant pipe to reservoir (tightening torque 9 Nm). Use oil filter strap for example to secure reservoir to prevent it turning.
Tighten the screws (C) (tightening torque 8 Nm). According to the type of bracket, there may be two screws present, with the same tightening torque but on opposite sides.

Check the distance from the refrigerant pipe (B) to the bolt (D) and to the holder. If necessary, fit a scuff guard (C) (e.g. a star-shaped piece of rubber as spacer Parts catalogue).

Note
- (A) with part number up to index has been replaced by a reservoir with the same part number as of index Parts catalogue, a scuff guard (C) (e.g. a piece of star-shaped rubber as spacer Parts catalogue) is always to be fitted.
Check the routing of the refrigerant pipes. They must not make contact with other components and the clearance must be sufficient to prevent scoring. Fit a scuff guard if necessary.
Re-install remaining components removed before.
Evacuate and refill the refrigerant circuit. Air conditioner with refrigerant R134a
Parts & tools for this job For 2008 SEAT Exeo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Exeo 2008 cabin filter
As an Amazon Associate we earn from qualifying purchases.