Cleaning evaporator
- Make
- SEAT
- Model
- Exeo
- Year
- 2008–2013
- Section
- Heating, air conditioning › Cleaning evaporator
Cleaning evaporator
Check whether the air conditioning unit is really the source of the odour by switching from fresh air mode to air recirculation mode.
Note
- ultrasonic air conditioner cleaner unit VAS 6189 A if it actually occurs in the evaporator.
Check the plenum chamber and the water drain valves fitted in it and clean these if necessary.
Check for odour from and contamination of dust and pollen filter Chapter “Removing and installing dust and pollen filter”.
Note
- fresh air blower V2 and does not therefore have to be removed for cleaning.
Start engine.
Select the lowest fresh air blower speed on the operating and display unit, Climatronic control unit J255 “air recirculation mode”, and switch the compressor “econ mode” off.
Open the dash panel vents and, on the operating and display unit, Climatronic control unit J255, set the lowest possible temperature for the driver's and front passenger's side (e.g. “Lo” temperature setting).
Close windows and sunroof of vehicle.
Select the lowest fresh air blower speed on the operating and display unit (Climatronic control unit J255) and set the air distribution to the “dash panel vents”.
Shake the bottle of cleaning fluid VAS 6189/1 and pour the fluid into the ultrasonic air conditioner cleaner VAS 6189 A, according to the operating instructions for the ultrasonic air conditioner cleaner VAS 6189 A.
Place the ultrasonic air conditioner cleaner VAS 6189 A in the passenger's footwell.
Start up the ultrasonic air conditioner cleaner VAS 6189 A (in accordance with the appropriate operating instructions) and position the outlet hose in such a way that the emerging vapour is drawn in by the fresh air blower V2 via the air recirculation opening of the air conditioning unit (in passenger's footwell behind glove box).
Close doors of vehicle.
Note
- The cleaning process takes roughly 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose.
Switch off ultrasonic air conditioner cleaner VAS 6189 A.
Open doors and vent vehicle for at least 10 minutes.
Remove ultrasonic air conditioner cleaner VAS 6189 A from vehicle and clean it in line with the appropriate operating instructions.
Switch ignition OFF.
Parts & tools for this job For 2008 SEAT Exeo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Exeo 2008 cabin filter
As an Amazon Associate we earn from qualifying purchases.