Checking condensate drain
Check routing of condensate drain hose; it must not be twisted or crushed.
Remove the condensation drainage valve and condensation drainage hose Chapter “Removing and installing condensate drain”
In area of hole (E) check gap between noise insulation mat and floor panel (noise insulation mat must not make contact with installed condensate drain valve).

Check condensate drain valve (C); it must not be gummed up with wax or underseal.
Note
- (C). The flap function is assumed by a coil formed by the valve.
Check for contamination of condensate drain hose (B) (pay attention to oval cross-section of hose (D)) and clean if necessary.
Use a piece of wire, for example, to check for contamination of condensate drain of air conditioner unit (F) and clean if necessary.
- In the event of moisture in passenger compartment:
Check the forced ventilation of the interior (via the luggage compartment) Chapter “Checking ventilation frame”.
Check signal for recognition of wiper operation at operating and display unit, Climatronic control unit J255.
Check dust and pollen filter for contamination and corresponding cover for correct installation Chapter “Removing and installing dust and pollen filter”.
Check the various control motors and the corresponding levers. Pay particular attention to position of air flow flap control motor V71 and air recirculation flap control motor V113 as well as the relevant flaps.
Check the measured value for the evaporator outlet temperature sender G263 (Read the measured value block, display group “010 ”).
If the measured value from the sender is too low under the conditions of use described by the customer (colder than 0° C for lengthy periods at an ambient temperature above 0°), follow the instructions on testing the refrigeration capacity Chapter “Refrigeration performance of the air conditioning: testing”.
If the measurement value of the evaporator outlet temperature sender G263 is too high under the operating conditions specified by the customer (although the air conditioner works trouble-free greater than, e.g. 10° C), check the evaporator outlet temperature sender G263 (the evaporator may ice-up resulting from an incorrect value).